Avalon Stoves 99200149 User Manual

Page of 8
ZC Kit – Large Pellet Insert
(99200149)
Page 4 of 8
10/9/06
© Travis Industries, Inc.
Minimum Enclosure Dimensions
Min.
Max.
Recommended
Height*
29”
31” **
30”
Width
36”
43” **
40”
Depth***
18”
22” ****
20”
* The enclosure height must be raised the same amount as the floor protection (e.g. if you are using 1” floor
protection, the min. height is 30” above the sub-floor).
** The maximum height is determined by the surround panel size (the surround panels are 32” tall).
*** When determining depth, include the facing material (drywall, tile, etc.) – see the illustration below.
**** When venting vertically, there is no maximum depth.
Width
Depth*
Height
When determining the position of the insert, consider 
the position of the framing behind the insert relative to 
the vent - see the illustration below.
* When determining the depth, include 
the facing material (drywall, tile, etc.).
7.5”
AAA
AAA
Pellet vent requires 3” 
clearance to combustibles.
A
A
A
TOP VIEW
NOTE: The enclosure may be 
raised.  The minimum 
distance from the base of the 
enclosure to the ceiling is 72”
Ceiling