L120 LOW LIMIT SWITCH 
This limit switch is mounted on the exhaust blower housing and has 2 main 
functions.  
1.  Should the fire happen to go out, for any reason, this limit switch will 
shut the stove off when the exhaust temperature drops below 
120deg F. 
2.  Upon starting the appliance, the AcuTron control board has a 15 
minute “Lighting Mode”, if the stove exhaust does not reach 120deg 
F in that 15 minutes the stove will shut off.  As soon as the stove 
exhaust does reach 120deg F, the limit switch opens and the 
AcuTron enters a 5 minute “Safety Delay” mode.  
 
F140 FAN LIMIT SWITCH 
Your pellet appliance has a convection fan control limit switch.  The room air 
fan's (F140) temperature limit snap switch automatically sets the fan on high 
when your stove is producing heat faster than the fan is carrying it into the 
room.  This may occur when the heat control lever is set at [3 or 4] and the 
FAN SPEED
 is set to a very low or off setting.  After the fan runs at this 
automatic high setting a few minutes, it may cycle back to its lower setting 
and may continue to cycle between [HIGH] and your selected setting.  The 
circulation (room air) fan cycling from high to low is a normal condition as well 
as a safety feature of your appliance. To compensate for the fan cycling, 
adjust the FAN SPEED to a higher setting.
  
 
L250 HIGH LIMIT SWITCH 
Your pellet appliance has a high temperature limit switch installed.  If 
the temperature at the back of the firebox reaches approximately 
250deg F., the switch will shut off the electricity going to the Vacuum 
Switch and to the Auger Motor.  The auger will automatically stop, and 
the appliance will shut down when the exhaust temperature cools 
(120deg F).  If this happens call your dealer or Dansons Customer 
Service (1-866-456-9269).  
 IT IS IMPORTANT TO FIND THE REASON WHY THE UNIT 
OVERHEATED
 
VACUUM SWITCH 
This safety device (mounted on the back panel pillar) detects vacuum in 
the exhaust system, firebox, and air intake.  If the exhaust blower fails, 
the vent pipe becomes plugged, the viewing door is open, or if you are 
out of pellets, this switch will sense that there is a lack of vacuum and 
will stop the auger from continuing to feed pellets. 
 
If the power does go out, the pellet appliance will stop 
running.  When the power comes back on, the stove will not 
restart if the switch is in the manual mode.   If the exhaust 
temperature is above 120deg F or the switch is in the manual 
position, the stove will start to feed pellets again and may re-
light itself. 
 
NOTE:  If power outages are a concern you may wish to purchase a back-up generator system.    
For further information contact your local Specialty Retailer, Certified HVAC Service Depot, or Dansons 
Group Inc. Customer Service Department at 1-866-456-9269.