Harman Stove Company SF2500A User Manual

Page of 20
8
SF2600 burner Set up
7”
12½”
7¾”
12⅞”
SF2600 Oil burner Setup
Nozzle                                                  80 Degree Solid Cone
Off Cycle Damper Setting (B)             No. (as low as it goes
Flamelock Setting (A)                                                     No. 
Combustion Air (C)                                                No.  to ¼
Draft - (Inches of water column)                               .06 to .08
Tests for CO² must be made without a fire in the wood/ coal firebox, and with all doors and draft controls 
completely closed. The burner should be fired for several minutes prior to taking a reading. Normal CO² 
reading is  to  with a stack temperature of 300 degrees or less. This would give you an efficiency of 84 
to 85 percent.