Runco LS-7 User Manual

Page of 100
56
Runco LS-7 Installation/Operation Manual
PRE
L
IMINAR
Y
Trigger 1: Select Trigger 1 from the Control menu to specify when the Trigger 1 port 
outputs 12 volts. There is a three-second delay before activation to prevent operation 
while selecting an aspect ratio.
• Lamp causes the port to output 12 volts whenever the lamp is on.
• 16:9 causes the port to output 12 volts whenever the 16:9 aspect ratio is chosen.
• Letterbox causes the port to output 12 volts whenever the Letterbox aspect ratio is 
chosen. The output stops if PIP is enabled (PIP source is set to anything other than off).
• 4:3 causes the port to output 12 volts whenever the 4:3 aspect ratio is chosen. The 
output stops if PIP is enabled (PIP source is set to anything other than off).
• 4:3 Narrow causes the port to output 12 volts whenever the 4:3 Narrow aspect ratio is 
chosen.  The output stops if PIP is enabled (that is, the PIP source is set to anything 
other than off).
• RS232 causes the port to output 12 volts when an RS232 screen trigger 1 “on” 
command is received and stop when a trigger 1 “off” command is received. The 12 volt 
output also stops when the projector is turned off.
Trigger 2: Select Trigger 2 from the Control menu to configure the Trigger 2 output. 
Trigger 2 operates identically to Trigger 1. 
Remote Code SetSelect Remote Code Set from the Control menu to specify the 
remote IR code set to which the LS-7 responds. The default is Set-1. Choose Set-2 if 
other equipment in the theater responds to commands from the LS-7 remote control in 
ways that are unexpected or undesirable. 
When you select a different remote code set on the LS-7, you must re-program the 
remote control unit to use that same code set. To do this, press and hold the LIGHT and 
ENTER buttons simultaneously for approximately five seconds. When the code set has 
changed, the remote control back-lighting “blinks” to visually confirm the change.
Table 6-1 lists the IR codes associated with each remote control button.
Auto SourceThis control chooses whether or not to scan for other active sources if the 
current source is not available. The default setting is Off.