Command and Response 
Examples
Here are some examples of serial commands and their responses:
Serial Command List
Table 6-1 lists all supported commands. 
Command
Command Data
Response
Power query when 
unit is powered on
(PWR?) [CR]
(0;PWR=1) [CR]
Set power to 0 (off)
(PWR=0) [CR]
(0;PWR=0) [CR]
Increment bright-
ness from 24 to 25
(BRT+) [CR]
(0;BRT=25) [CR]
Invalid command 
(ZZZ=0) [CR]
(1;ZZZ=0) [CR]
Invalid parameter 
(received string, 
expected integer) 
(CON=”Some string”) 
[CR]
(9;CON=”Some string”) 
[CR]
Table 6-1. Serial Commands
Setting
Command 
Code
Read/
Write
Inc/
Dec
Min 
Value
Max 
Value
String?
Notes
Advanced Color Temp Auto Color 
Enable
AAC
R/W
No
0
1
No
0 = Off; 1 = On
Advanced Color Temp Diagnostic 
Color
AAD
R/W
No
0
6
No
0  =  White
1 = Red
2 = Green
3 = Blue
4 = Yellow
5 = Cyan
6 = Magenta
Apply Image Alignment Values
AIA
R/W
No
0
1
No
0 = Off; 1 = On
Altitude
ALT
R/W
No
0
1
No
0 = Auto
1 = High
Auto New Firmware Check
ANF
R/W
No
0
1
No
0 = Off; 1 = On
Auto Power Off Enable
APE
R/W
No
0
1
No
0 = Off; 1 = On
Auto Power Off Timer
APT
R/W
Yes
1
24
No
Auto Perform Upgrade
APU
R/W
No
0
1
No
0 = Off; 1 = On
Aspect Ratio Copy
ARC
W
No
N/A
N/A
No
Action will be performed on any 
setting value
Aspect Ratio Paste
ARP
W
No
N/A
N/A
No
Aspect Ratio
ASP
R/W
No
0
6
No
0 = 4:3
1 = 16:9
2 = Letterbox
3 = VirtualWide
4 = Cinema
5 = Virtual Cinema
6 = Native