Runco LS-3 User Manual

Page of 105
Runco LS-3/LS-5 Installation/Operation Manual
53 
PRE
L
IMINAR
Y
DLP Frame Rate: Select DLP Frame Rate from the Advanced menu to choose the 
output frame rate. You can have the LS-3/LS-5 automatically determine the optimum 
frame rate, or you can force it to use a specific frame rate. 
 
• The default setting, Auto, frame locks to the main source if it has a vertical refresh rate 
of between 48 and 62Hz. Vertical refresh rates of from 24 to 31Hz are doubled. Frame 
rates between 31 and 48Hz and greater than 62Hz are converted to 60Hz.
• Select 48Hz to force the output frame rate to 48Hz. Use this setting to eliminate 2:3 
pull-down judder with 60Hz film-based sources.
• 50Hz and 60Hz force the output frame rate to 50Hz and 60Hz respectively.
Color Gamut: Select Color Gamut from the Advanced menu to select a color gamut 
(range) that may be different from the default color gamut. 
Each setting defines the precise hue of each primary (red, green and blue) and secondary 
(yellow, cyan and magenta) color component used to generate the millions of colors 
produced in displays. Changing either or both of these numbers changes the hue of the 
color and relocates the “triangle” for possible colors. For example, changing the x/y 
coordinates for red moves the color closer to either orange or violet, which in turn affects 
all displayed colors having a red component.
• Auto automatically chooses the appropriate color gamut:
• SMPTE C for NTSC, 480i and 480p sources. 
• EBU for PAL, SECAM, 576i and 576p sources.
• REC709 for all other sources.
• REC709 chooses the REC709 color gamut.
• Select SMPTE-C to choose the SMPTE-C color gamut.
• Select EBU to choose the EBU color gamut.
• Select Native to use REC709 for cyan, magenta, and yellow and uncorrected values 
for red, green, and blue. 
Table 4-3 lists the x- and y-coordinates for each primary and secondary color component. 
If PIP is active, the LS-3/LS-5 converts the PIP source frame rate to 
the same frame rate as the main source.
Table 4-3. x/y Color Gamut Values 
Primary 
Color
Color Gamut Settings and Associated x/y Values
REC709
SMPTE “C”
EBU
x
y
x
y
x
y
Red
0.640
0.330
0.635
0.340
0.640
0.330
Yellow
0.419
0.505
0.421
0.506
0.418
0.502
Green
0.300
0.600
0.305
0.595
0.290
0.600
Cyan
0.225
0.329
0.228
0.326
0.220
0.329
Blue
0.150
0.060
0.155
0.070
0.150
0.060
Magenta
0.321
0.154
0.318
0.162
0.328
0.158
Note