Runco Q-750I User Manual

Page of 108
Q-750i Series Installation/Operation Manual
41 
PRE
L
IMINAR
Y
Once the proper lens angle has been set, firmly tighten the Yaw/X-Adjustment Levers to 
secure the lens in place. 
Geometry: 
1.
Input an anamorphic cross-hatch test pattern to the projector.
2.
Unscrew the Anamorphic Lens just enough to allow it to rotate freely.
3.
Grasp the lens by the center ring and rotate the lens until the image is properly 
anamorphic: 
4.
When the image geometry appears correct, tighten the 
Anamorphic Lens Set Screw (item #10) to secure the lens in place. 
(When viewed from the front, the rear opening on the anamorphic 
lens should appear as a tall, narrow oval.)
 
Focus: Finally, rotate the Focus Ring on the anamorphic 
lens to fine-tune the optical focus. 
Wrong Position
Correct Position
Wrong Position
Correct Position
F
O
C
U
S