Test Patterns: The Q-750i has numerous internal test patterns that are useful to 
technicians for advanced calibration, measurement and fault isolation purposes. To 
access them, select Test Patterns from the Service menu and set it to On
The available test patterns are:
• White
• Black
• Red
• Green
• Blue
• Cyan
• Magenta
• Yellow
• ANSI Checkerboard
• Horizontal Gray Ramp
• Focus  Grid
Press 
 or 
 on the remote control unit or built-in keypad to cycle through the test 
patterns. 
To turn test patterns off, press any key other than 
 or 
 on the remote control unit or 
built-in keypad.
AltitudeSelect Altitude from the Service Menu to control the operation of the projector’s 
cooling fan. 
In most cases, the default setting (Auto) maintains the correct operating temperature. If 
the projector frequently turns off due to overheating, or in certain high-altitude operating 
environments, you may need to change this setting to High
The OSD menus are not available when in “test pattern” mode.