Runco X-200i User Manual

Page of 118
60
Runco X-200i Series Installation/Operation Manual
PRE
L
IMINAR
Y
Brightness: On your external test pattern source, select a PLUGE pattern. (PLUGE is an 
acronym for “Picture Line-Up Generation Equipment.”) Figure 4-5 shows a typical PLUGE 
pattern.
Figure 4-5. Typical PLUGE Pattern for Adjusting Brightness
PLUGE patterns vary but generally consist of some combination of black, white and gray 
areas against a black background. The example above includes two vertical bars and four 
shaded boxes.
Select Brightness from the Main menu. Use the 
 or 
 buttons to adjust the level so that:
• The darkest black bars disappear into the background. 
• The dark gray areas are barely visible.
• The lighter gray areas are clearly visible.
• The white areas are a comfortable level of true white.
• The image contains only black, gray and white (no color).
Below Black
Above Black