Sony HT-AS5 User Manual

Page of 80
28
GB
Tip
When you face the speaker towards the optimizer 
microphone, you will get a more accurate 
measurement.
1
Press AMP MENU.
“LEVEL” appears on the display.
2
Press 
V/v repeatedly until 
“A.CAL MENU” appears, then 
press  
or 
b.
3
Press 
V/v repeatedly until 
“A.CAL START” appears, then 
press .
Measurement starts in a few seconds.
While the time is counting down, stand 
away from the measurement area to avoid 
measurement error.
The measurement process will take 
approximately 30 seconds to complete.
The table below shows the display when 
measurement starts.
Notes
• If “CHECK MIC” appears, you cannot perform 
the Auto Calibration. Connect the optimizer 
microphone, then perform the Auto Calibration 
again.
• If “PHONES” appears, you cannot perform the 
Auto Calibration. Disconnect the headphones 
from the S-AIR product you are using, then 
perform the Auto Calibration again.
Tips
• When Auto Calibration starts:
– Stand some distance from the speakers and the 
listening position to avoid measurement failure. 
This is because test signals are output from the 
speakers during measurement.
– Avoid making noise to get a more accurate 
measurement.
• The Auto Calibration function will be canceled 
when you do the following during the 
measurement process:
– Press ?/1 or 
.
– Press input buttons on the remote or INPUT 
SELECTOR on the subwoofer.
– Change the volume level.
– Press AMP MENU.
Performing Auto Calibration
BD
DVD
SAT/
CATV
TV
VIDEO
SA-CD/
CD
DMPORT
TUNER
MENU
Input 
buttons
?/1 
2 +/–
AMP 
MENU
V/v/B/b, 
 
Measurement for
Display
Speaker existance
TONE
Speaker gain, distance, 
frequency response
T. S. P.