Symptom
Standby Button State
Possible Cause
Action
The lamp will not ignite
Red
The projector is cooling 
down.
Wait until the projector 
completes its cooling 
cycle. Once the Standby 
button turns amber, you 
can press the Standby 
button again.
Orange
The lamp has expired
Replace the Lamp and 
press the Standby button 
to start the projector.
The lamp ballast may 
have stopped functioning.
Contact 3M for service.
Flashes RED once every 
second
There is a problem with 
one of the cooling fans.
Follow the maintenance 
procedure on page 31 and 
try starting the projector 
again. If cleaning does 
not resolve the problem, 
contact 3M for service. 
The lamp will not ignite 
or has turned off.
Flashes RED twice every 
second
The projector has 
overheated due to elevated 
ambient temperature or 
altitude, or blocked air 
vents.
Follow the maintenance 
procedure on page 31. 
Unplug the power cord 
and reconnect and then 
try again. If cleaning does 
not resolve the problem, 
contact 3M for service.
Flashes RED four times 
every second
The projector’s 
processor had a 
communication error 
due to electromagnetic 
interference on the 
communication cable 
connecting the Control 
port on the projector 
and I/O module or poor 
quality communication 
cable.
Make sure the cable 
connecting the Control 
Port on the projector 
to the I/O module does 
not cross power cables 
or other communication 
cables. If it does, reroute 
the cables so that they 
do not cross.  If the 
communication cable 
between the projector and 
the I/O module is longer 
than 4m (13 ft), consider 
using the 3M I/O Module 
Cable Extender P/N: 
78-6972-0027-3.