FRONT PANEL
Mains Switch
Use the mains switch to switch the unit’s power on. A soft-start function prevents inrush 
current peaks on the mains, additionally preventing the mains line protection switch from 
activating during the amp’s power-on operation. Loudspeaker outputs are activated via 
relay switching with a delay of approx. 2 seconds, which effectively eliminates eventual 
power-on noise. 
During  this  delay  period,  the  Protect  LED  lights  to  confirm  correct  operation  of  the 
protection circuitry.
Protect (PROT)
A lit Protect LED indicates that one of the integrated protections against thermal overload, 
short-circuit … has been activated. The audio channels’ protection circuits operate in-
dependent  from  each  other. At  the  occurrence  of  failure  or  overload  conditions  the 
affected  power  amp  channel  is  separated  from  the  load  connected  via  output  relay, 
preventing  the  connected  loudspeaker  systems  and  the  power  amplifier  itself  from 
being damaged. Whatever caused the fault – e.g. a short-circuited speaker cable – needs 
to be remedied. In case of thermal overload you have to wait until the power amplifier 
automatically returns to normal operation. 
Limiter
The Limit indicator lights as soon as the integrated dynamic limiter is being activated 
and the power amp is driven at the clipping limit or generally at its maximum capacity. 
Short-term blinking is not a problem, because the internal limiter trims input levels of up 
to +21dBu down to a THD+N of approximately 1%. If, on the other hand, this LED lights 
constantly,  reducing  the  volume  is  strongly  recommended  to  prevent  the  connected 
loudspeaker systems from being damaged by probable overload.
Level Indication
The level indicators signify the power amplifier’s current modulation. The -30dB LED 
starts  lighting  at  approx.  30dB  below  full  modulation  while  the  -10dB  LED  lights  at 
approx.  10dB  below  full  modulation.  Shorted  speaker  cables  or  the  activation  of  a 
protection circuit causes these indicators to go out.
Power
The Power indicator lights when switching the power amplifier on. If the power on LED 
does  not  light  please  check  to  make  sure  the  unit  is  plugged  in  or  that  the  primary 
fuse is not blown.  If the fuse is blown please contact an authorized service center.