Emerson Series 3000 MVD User Manual
Configuration and Use Manual
151
Operation Mode – Batch
Operation
Mode
–
Ba
tc
h
T
o
tali
z
e
rs
and
In
ven
ven
tories
Ope
ration
Mode – Custod
y T
ra
ra
n
s
fer
Op
eratio
eratio
n M
o
d
e
Figure 18-1
Series 3000 display in batch mode
18.3.1
Function buttons
In Figure 18-2, the display shows that the batch target is 12.3 kg.
•
When you press
START
, the discrete outputs assigned to the pump and valve are activated, and
flow starts.
•
When the target amount has passed through the flowmeter, the discrete outputs assigned to the
pump and valve are deactivated, and flow stops.
pump and valve are deactivated, and flow stops.
The labels on the three function buttons are changed during the batch run to show the actions you can
perform at each point.
perform at each point.
To start the batch, press the button on the left, labeled
START
. Figure 18-2 shows what happens.
DEVICE 1
Preset 1
Actual
0.0
Target
kg
12.3
START
HELP
VIEW
Cursor control
buttons
buttons
Security
button
button
Editing
cursor
cursor
Backlit
display
Function buttons
Note: If the petroleum measurement application or the enhanced density application is installed
and the batch controller is measuring standard volume, net volume, or net mass, actual and
target values indicate net totals rather than gross totals.
and the batch controller is measuring standard volume, net volume, or net mass, actual and
target values indicate net totals rather than gross totals.