Emerson Series 3000 MVD User Manual
Configuration and Use Manual
259
Rela
y In
stal
latio
n
Series
3
000
Men
u
s
Defaults
Spec
ifications – Model
3
100
Appendix C
Specifications – Model 3100
C.1
Overview
The Model 3100 accessory features relay packs for interfacing with high-energy solenoids, pump
starters, or other devices.
starters, or other devices.
C.2
Relay packs
The Model 3100 contains three relays with the following characteristics:
•
Solid state, SPST
•
Rated at 24–250 VAC, 40 mA–5 A; or 0–70 VDC, 5 A
•
Energized by discrete outputs
C.3
Hazardous area classifications
C.3.1
ATEX
Zone 2, complying with ATEX Directive (94/9/EC) for Group II, Category 3G, according to
CENELEC standard prEN 50021:1998 and marked as:
CENELEC standard prEN 50021:1998 and marked as:
•
EEx n V II T4
•
KEMA 97 ATEX 4940 X
•
Ambient temperature –20 to +60 °C (–4 to +140 °F)
C.3.2
UL and CSA
Class I, Division 2, Groups A, B, C, and D