Product is patented in the U.S., Canada, and Mexico. 
 
PVI INDUSTRIES, LLC 
FORT WORTH, TEXAS 76111 
PV 6291  9/07
 
(800) 784-8326  
•  www.pvi.com 
MAXIM • PACKAGED GAS WATER HEATER
 
POLYSHIELD
®
  POLYMER-LINED STORAGE TANK 
90 GALLON TANK SERIES 
 
MODEL NUMBER 
40 P 90A-MXG 
54 P 90A-MXG 
 
GPH Recovery at 40° to 120° F 
500 
670 
 
GPH Recovery at 40° to 140° F 
400 
540 
 Input 
Btu/h 
399,000 
540,000 
Minimum inlet flow gas pressure – " W.C. 
4.5 
4.0 
Cold Inlet - NPT 
Hot Outlet - NPT 
Drain - NPT 
I - Beam Skids 
3 x 34-1/2 
3 x 34-1/2 
F Overall 
Height 
64 
72 
Flue Outlet Diameter 
Gas Inlet - NPT 
3/4 
Motor HP  120 V, 1Ø, 60 Hz. 
1/3 
1/3 
K Motor 
Amps 
Height to Outlet 
53 
61 
Height to Inlet 
28 
36 
 
Approx. Shipping Weight - lbs 
1010 
1130 
  Recoveries based on 83% thermal efficiency. ASHRAE 90.1 compliant. 
  Dimensions are in inches unless otherwise specified. 
*  The information presented is for natural gas 0.6 S.G. – For operation with propane (LP gas), consult the factory. 
  For standard and optional equipment, see form # PV 6141. 
 
 
 
 
 
 
 
STANDARD GAS PRESSURE REQUIREMENTS: 
SEE TABLE FOR MINIMUM PRESSURE BY MODEL NUMBER. 
MAXIMUM STATIC INLET GAS PRESSURE: 14" W.C. 
FOR GAS PRESSURES OUTSIDE OF THIS RANGE,  
CONTACT YOUR PVI REPRESENTATIVE. 
 
STANDARD ELECTRICAL REQUIREMENTS: 
CONTROL VOLTAGE:  120V, 1Ø, 60 HZ., 2 AMPS 
MOTOR VOLTAGE: 120V, 1Ø, 60 HZ. 
SEE ABOVE CHART FOR BLOWER MOTOR AMPS 
 
VENTING REQUIREMENTS: 
-.02" TO -.06" W.C. (NEGATIVE PRESSURE). 
TYPE B VENTING 
THE ENTIRE VENT SYSTEM SHOULD NEVER BE SIZED BASED UPON THE 
VENT CONNECTION DIAMETER EXCLUSIVELY. 
FOR PROPER VENT SIZING, CONSULT THE NATIONAL FUEL GAS CODE 
UNDER "FAN-ASSISTED". 
PVI RESERVES THE RIGHT TO CHANGE THE DESIGN AND 
SPECIFICATION WITHOUT NOTICE 
 
1. Control Enclosure 
2. ASME Temperature & 
  Pressure Relief Valve 
3. 3” NPT Handhole