PVI Industries 500PHE250A-TPL Leaflet

Page of 1
Product is patented in the U.S., Canada, and Mexico. 
 
PVI INDUSTRIES, LLC 
FORT WORTH, TEXAS 76111 
PV 6555  02/25/04
 
(800) 784-8326  
•  www.pvi.com 
LOW NO
x
 TURBOPOWER
®
 • PACKAGED WATER HEATER 
POLYSHIELD
®
  POLYMER-LINED STORAGE TANK 
TANK SERIES 250 GALLONS HORIZONTAL
 
 
Recovery gph 
c
 
Dimensions (inches) 
Blower  
Motor 
MODEL 
NUMBER 
40° - 120°F  40° - 140°F 
INPUT 
Btu/h 
Min. Inlet 
Flow Gas 
Pressure 
" W.C. 
e 
SCAQMD Energy 
Model No. 
A B C  J 
d HP Amps 
Shipping
Weight
lbs  
250 PHE 250A-TPL 
250 
200 
199,000 
4.5 
2TPL 
199 MBtu/h 
23 
1/2 
16 
1/3 
1395 
375 PHE 250A-TPL 
375 
300 
300,000 
4.5 
3TPL 
299 MBtu/h 
23 
3/4 
16 
1/3 
1400 
500 PHE 250A-TPL 
500 
400 
399,000 
4.5 
4TPL 
399 MBtu/h 
23 
3/4 
16 
1/3 
1400 
c Recoveries based on 83% thermal efficiency. ASHRAE 90.1 compliant for efficiency and standby loss. 
d “J” dimension is for the burner housing only – gas train may exceed this dimension. 
e Standard gas train. 
*  The information presented is for natural gas 0.6 S.G. 
  Dimensions are in inches unless otherwise specified. 
  For standard and optional equipment, see form #PV6550. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
STANDARD GAS PRESSURE REQUIREMENTS: 
SEE TABLE FOR MINIMUM PRESSURE BY MODEL NUMBER. 
MAXIMUM STATIC INLET GAS PRESSURE IS 14" W.C.  
FOR GAS PRESSURES OUTSIDE OF THIS RANGE,  
CONTACT YOUR PVI REPRESENTATIVE. 
 
VENTING REQUIREMENTS: 
-.02" TO -.06" W.C. (NEGATIVE PRESSURE). 
TYPE B VENTING. 
ENTIRE VENT SYSTEM SHOULD NEVER BE SIZED BASED UPON 
THE VENT CONNECTION DIAMETER EXCLUSIVELY. CHECK 
NATIONAL FUEL GAS CODE UNDER "FAN ASSISTED." 
STANDARD ELECTRICAL REQUIREMENTS: 
CONTROL VOLTAGE:  120V, 1Ø, 60 HZ., 2 AMPS. 
MOTOR VOLTAGE:  1/3 HP ARE 120V, 1Ø, 60 HZ. 
 
 
  208V, 230V AND 460V MOTORS ARE AVAILABLE BUT WILL 
  REQUIRE A SEPARATE 120V/2 amps CONTROL CIRCUIT OR AN 
  OPTIONAL CONTROL CIRCUIT TRANSFORMER. 
 
PVI RESERVES THE RIGHT TO CHANGE THE DESIGN AND 