PVI Industries Gas-Fired Water Heater Leaflet

Page of 1
 
See complete warranty and/or service policy for details 
PLATINUM
®
 
CONDENSING GAS-FIRED WATER HEATER 
POLYSHIELD
®
 
 POLYMER-LINED TANK 
 PVI reserves the right to change 
the design and specification 
without notice. 
PV6801   10/08 
PVI INDUSTRIES, LLC 
FORT WORTH, TEXAS 76111 
(800) 784-8326 ▪ (817) 335-9531 ▪  www.pvi.com 
STANDARD FEATURES AND EQUIPMENT 
 
• 
POLYSHIELD
®
 polymer-lined tank with 5-year warranty   
• 
Five-year heat exchanger warranty   
• 
One-year cost-free service policy    
• 
Factory authorized startup 
• 
Up to 94% thermal efficiency  
• 
Electronic temperature control with LED readout; accurate to ± 1°F  
• 
Removable heat exchanger with non-ferrous waterside construction and solid copper fire tubes 
• 
100% submerged combustion  
• 
Heat exchanger ASME stamped for 160 psi operating pressure 
• 
Storage tank ASME stamped for 160 psi operating pressure and National Board of Pressure Vessels Registered 
• 
Nonferrous, removable fittings at all tank connections  
• 
Fan assisted, pre-mix, stainless steel burner 
• 
Two safety shut off valves (single body) 
• 
NOx emission levels compliant with SCAQMD 
• 
Air proving switch 
• 
Electronic combustion sequencer and safeguard with pre-purge 
• 
Operating thermostat 
• 
Redundant high limits with automatic reset 
• 
ASME-rated temperature and 150 psi pressure relief valve 
• 
Drain valve
 
 
• 
Fiberglass insulated tank 
• 
Durable, corrosion-resistant, polyethylene jacket 
• 
Heavy-duty steel stand 
• 
Support stand is designed to allow tank to be rotated to horizontal position for heat exchanger removal  
• 
23"-diameter tank access after heat exchanger removal 
• 
ASHRAE 90.1 compliant for thermal efficiency and standby loss 
• 
UL listed for PVC venting material  
• 
UL listed for zero clearance from combustible walls (non-combustible floor only) 
• 
UL listed for NSF-5 compliance  
• 
FM compliant 
OPTIONAL FEATURES AND EQUIPMENT 
 
 
Electronic low water cutoff 
 
Manual-reset, immersion temperature limiting device 
 
Air intake assembly for remote combustion air (requires field connection to ductwork supplied by others) 
 
Water pressure gauge 
 
L.P. gas operation 
 
Condensate neutralization system 
 
CSD-1 and IRI compliant components (includes manual reset electronic low water cut off and manual reset 
 
temperature limiting device) 
 
AGA-rated temperature and pressure relief valve 
 
Tridicator (field installed) 
 
Lifting attachments 
 
Other agency compliance _______________________ (consult factory)