Rinnai RV53E User Manual

Page of 60
 
RV53i & RV53e Operation and Installation Manual 
     WARNING 
  Safety Behaviors and Practices
   
 
 
 
 
 
 
 
 
 
 
 
 
    
•  Keep the area around the appliance clear and free 
from combustible materials, gasoline, and other 
flammable vapors and liquids. 
•  Any alteration to the appliance or its controls can be 
dangerous and will void the warranty. 
•  Always check the water temperature before entering 
a shower or bath. 
•  Do not use this appliance if any part has been under 
water.  Immediately call a qualified service 
technician to inspect the appliance and to replace 
any part of the control system and any gas control 
which has been under water. 
 
  Safety Definitions
   
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
This is the safety alert symbol.  This symbol alerts you to potential hazards that can kill or hurt you and 
others.
 
Indicates an imminently hazardous situation which, if not avoided, will result in death or 
serious injury. 
Indicates a potentially hazardous situation which, if not avoided, could result in death or 
serious injury. 
Indicates a potentially hazardous situation which, if not avoided, could result in minor or 
moderate injury.  It may also be used to alert against unsafe practices. 
     DANGER 
     CAUTION 
     WARNING 
Consumer Safety Information 
  Safety Features 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
•  Overheat:  The appliance will automatically shut 
down when the appliance exceeds a predetermined 
temperature. 
•  Flame Failure:  The appliance will automatically 
shut down if the burner flame is extinguished. 
•  Power Failure:  The appliance will cut off the gas if 
it loses electrical power. 
•  Power Surge Fuse:  A glass fuse protects against 
overcurrent.  If the fuse blows then all indicator 
lamps will be off. 
•  Fusible Link:  In case the overheat feature does 
not prevent the temperature from rising then the 
fusible link will break shutting off the appliance. 
The Rinnai water heater is one of the most advanced 
water heaters available.  It provides a continuous 
supply of hot water at a preset temperature.  This 
appliance is direct vent where air is brought in from the 
outside and combustion gases are exhausted to the 
outside. 
While electricity, water, and gas supplies are 
connected, the Rinnai water heater produces hot water 
whenever a hot water tap is open. 
Ignition is electronic.  There is no pilot light consuming 
gas while the water heater is not being used.  The gas 
burner lights automatically when the hot water tap is 
opened and goes out when the tap is closed. 
Installation of the temperature controller is highly 
recommended.  The temperature controller can set the 
temperature within a specific range and can provide 
error codes to diagnose any problems.   
The temperature of the outgoing hot water is constantly 
monitored.  The Rinnai water heater may adjust the 
water flow in order to maintain the temperature setting.  
The water flow may vary from summer to winter due to 
the difference in ground water temperature. 
Description of Operation