Appliance Location. 
The wall or structure on which it is mounted must be capable of supporting the weight of 
the appliance (15 kg) and associated pipework.  Ensure that suitable screws or bolts are 
used to secure the water heater to the wall.  Bracket and fixing hole locations are shown 
on the template included.  The top bracket has a keyhole slot so that the appliance can 
be hung on one screw, and then the other fixings can be added to secure the unit. 
The heater must be installed in the vertical position with the gas and water connections 
on the underside pointing vertically downward.  The heater must be installed internally. 
The appliance should be placed as close as practical to the most frequently used hot 
water outlet point or points to minimise the delay time for hot water delivery. For 
installations where the distance between the unit and hot water outlet points is 
considerable, the appliance can also be fitted in a 'flow and return system' which 
minimises the waiting time for hot water delivery. Alternatively, multiple appliances can 
be strategically placed to service outlet points with minimal delay time. Contact Rinnai or 
your supplier for further information. 
When positioning appliance the flue terminal clearances must be in accordance with lo-
cal requirements.  Consideration should be given to other appliances, openings, and 
boundaries. Multiple heater installations can be installed with the heaters manifolded 
together.  The minimum distance required between the heaters may then be based on 
the necessary clearances between flue terminals.   
The appliance must be in an accessible location. Sufficient clearances shall allow 
access to, and removal of, all serviceable components. The following clearances should 
be followed. 
If the unit is installed on a 
combustible wall such as wood 
there must be a 45mm gap 
between the wall and the back 
of the unit.  Brackets are avail-
able to space the unit this far 
off of the wall. 
In case the side wall next to 
the appliance is flammable 
material there must be at least 
50mm between the side of the 
appliance and the combustible 
wall.
The illustration shows the 
clearances necessary for    
servicing, on a non-
combustible wall. 
INSTALLATION INSTRUCTIONS - POSITIONING