GSW POWER VENTED GAS FIRED WATER HEATER User Manual
-12-
Important: in locations where a sump pump failure, flooding or
exposure to water may be present, a ground fault receptacle is
recommended.
exposure to water may be present, a ground fault receptacle is
recommended.
VI)
Lighting and Operating Instructions
WARNING
READ BEFORE PROCEEDING
If you do not understand and follow these
instructions, a fire or explosion may result.
instructions, a fire or explosion may result.
This
Superflue
Water Heater is equipped with an electric
combination thermostat / gas valve control and an ignition device
that lights the burner.
that lights the burner.
DO NOT ATTEMPT TO LIGHT
THIS WATER HEATER MANUALLY!
The control
contains internal self-diagnostic features and an external LED
monitor light (Figure 11).
monitor light (Figure 11).
During operation a flashing LED indicates a burner or ignitor
failure, putting the system into a safety lockout condition. This
control uses three attempts at ignition before locking out. To
reset a system in lockout, disconnect electrical power, wait ten
seconds and re-energize. If the system fails to re-start, see
trouble shooting section.
failure, putting the system into a safety lockout condition. This
control uses three attempts at ignition before locking out. To
reset a system in lockout, disconnect electrical power, wait ten
seconds and re-energize. If the system fails to re-start, see
trouble shooting section.
A “constant on” LED indicates an unserviceable fault within the
control, and cannot be reset. The complete control must be
replaced.
control, and cannot be reset. The complete control must be
replaced.