Honeywell T7100D User Manual

Page of 16
T7100D,E,F MICROELECTRONIC COMMERCIAL THERMOSTATS AND Q7100A,C,D SUBBASES
68-0163—3
2
ORDERING INFORMATION
When purchasing replacement and modernization products from your TRADELINE® wholesaler or distributor, refer to the
TRADELINE® Catalog or price sheets for complete ordering number.
If you have additional questions, need further information, or would like to comment on our products or services, please write or
phone:
1.
Your local Home and Building Control Sales Office (check white pages of your phone directory).
2.
Home and Building Control Customer Logistics
Honeywell Inc., 1985 Douglas Drive North
Minneapolis, Minnesota 55422-4386
In Canada—Honeywell Limited/Honeywell Limitée, 35 Dynamic Drive, Scarborough, Ontario M1V 4Z9.
International Sales and Service Offices in all principal cities of the world. Manufacturing in Australia, Canada, Finland, France,
Germany, Japan, Mexico, Netherlands, Spain, Taiwan, United Kingdom, U.S.A.
SPECIFICATIONS
IMPORTANT
The specifications given in this publication do not
include normal manufacturing tolerances; therefore,
an individual unit may not exactly match the listed
specifications. Also, this product is tested and
calibrated under closely controlled conditions, and
some minor differences in performance can be
expected if those conditions are changed.
T7100 Models:
See Table 1.
Table 1. T7100 Thermostat Models.
a
Depends on the model.
Q7100 Models:
See Table 2.
Table 2. Q7100 Subbase Models.
a
Depends on the model.
Electrical Rating:
Input Power: 18 to 30 Vac, 50/60 Hz.
Load Rating: See Table 3.
Table 3. Maximum Amperes at 18 to 30 Vac.
Relay
Running
(A)
Inrush (A)
Heat
.02 to 1.5
3.5 at 200,000 cycles
Cool
.02 to 1.5
7.5 at 100,000 cycles
Fan, Reversing Valve,
Emergency Heat
.02 to 0.5
2.5 at 200,000 cycles
Temperature:
Setpoint Range:
40
°
 to 90
°
F (4
°
 to 32
°
C).
Display Range:
Controlled: 30
°
 to 110
°
F (1
°
 to 43
°
C).
Outdoor: -30
°
 to 120
°
F (-34
°
 to 49
°
C).
Display Updates:
Controlled: updated every minute.
Outdoor: displayed on demand and updated every
10 minutes.
Differential:
3
°
F (1.5
°
C). Fixed on D and E models.
2
°
F (1
°
C). Adjustable from 2
°
-10
°
F (1-5
°
C) on
F models.
Minimum Off Time (Cooling and Heat Pumps):
5 minutes 
±
 0.5.
Operating Ambient Temperature:
40
°
 to 110*F (4
°
 to 43
°
C).
Shipping Temperature  Range:
Minus 20
°
 to 130
°
F (-29
°
 to 54
°
C).
Approvals:
European Community Mark (CE) Listed.
Operating Relative Humidity Range:
5% RH to 90% RH, noncondensing.
Mounting:
The thermostat mounts on a subbase. The subbase mounts
horizontally on a wall or 2 in. x 4 in. outlet box with the screws
provided. Leveling is not required.
Model
Use With
System
a
Fig.
T7100D
Q7100A
Conventional
17 and 19
T7100E
Q7100C,D
Heat pump
18 and
20-22
T7100F
Q7100A,C,D
Conventional or
heat pump
17-22
Use  
Stages
a
Q7100
With
System
Heat   Cool  
Fig.
A
D or F Conventional
1 or 2 1 or 2
17 and 19
C
E or F
Heat pump
1, 2
or 3
1 or 2
18 and
20-22