Honeywell T8411R User Manual

Page of 6
T8411R ELECTRONIC HEAT PUMP THERMOSTAT
3
69-1481-1
Fig. 4. Restrict wiring to shaded area.
Refer to Fig. 5 for typical wiring hookups. A letter code is 
located near each terminal for identification.
1. Loosen the terminal screws on the wallplate and 
connect the system wires. See Fig. 5.
2. Securely tighten each terminal screw.
3. Push the excess wire back into the hole.
4. Plug the hole with nonflammable insulation to pre-
vent drafts from affecting the thermostat.
Mounting Thermostat to Wallplate
1. Engage the tabs at the top of the thermostat and 
wallplate.
2. Swing down the thermostat and press the lower 
edge of the thermostat onto the wallplate to latch. 
See Fig. 6.
Fig. 5. T8411R two-stage heat and one-stage cool wiring diagram with manual changeover.
KEEP WIRING IN
SHADED AREA
MOUNTING 
SCREW HOLE
MOUNTING 
SCREW HOLE
WIRING ENTRANCE
HOLE
M11331A
G
C
R
Y
W1
L
W2
E
B
O
1
NOT ALL MODELS HAVE BOTH O AND B TERMINALS.
1
L1 
(HOT)
L2
1
1
2
2
POWER SUPPLY. PROVIDE DISCONNECT MEANS AND OVERLOAD PROTECTION AS REQUIRED.
REMOVE JUMPER, WHEN SUPPLIED, FOR SYSTEMS WITH SEPARATE HEATING COMPRESSOR CONTACTOR (W1 SEPARATE FROM Y).
NOT ALL MODELS HAVE BOTH O AND B TERMINALS.
SYSTEM 
SWITCH
HEAT
OFF
COOL
R
W2
L
B
O
Y
EM. HT.
W1
E
AUXILARY
HEAT RELAY
CHANGEOVER 
VALVE HEAT
CHANGEOVER 
VALVE COOL
COMPRESSOR
CONTACTOR
COMPRESSOR
CONTACTOR
HEAT
FAN RELAY
RELAY
EMERGENCY
HEAT RELAY
G
C
THERMOSTAT
LOGIC
THERMISTOR
SENSOR
POWER
SUPPLY
ON
AUTO
STAGE 2 RELAY
STAGE 1 RELAY
FAN SWITCH
M11333A
3
3