ritetemp 8022 User Manual

Page of 9
Install guide 8022
1  Location
Caution
Tools 
To avoid electrical shock and to prevent damage to the furnace, air conditioner, 
and thermostat, disconnect the power supply before beginning work. 
This can be done at the circuit breaker, or at the appliance.
2 Remove old unit
3 Mount the 8022
C  A  U  T  I  O  N
Your thermostat is a precise instrument.
Please handle it with care.
Turn off electricity to the appliance before installing or 
servicing thermostat or any part of the system. Do not 
turn electricity back on until work is completed.
Do not short (jumper) across electric terminals at 
control on furnace or air conditioner to test the system. 
This will damage the thermostat and void your warranty.
All wiring must conform to local codes and ordinances.
This thermostat is designed for use with 24 volt AC and 
millivolt systems. The thermostat should be limited to a 
maximum of 1.0 amps; higher amperage may cause 
damage to the thermostat. 
On replacement installations, mount the new thermostat in place of the 
old one if possible. 
On new Installations, follow the guidelines listed below. 
Locate the thermostat on an inside wall, about 5 ft. (1.5m) above the 
floor, and in a room that is used often.
Do not install it where there are unusual heating conditions, such as: in 
direct sunlight; near a lamp, radio, television, radiator register, or 
fireplace; near hot water pipes in a wall; near a stove on the other side 
of a wall.
Do not locate in unusual cooling conditions, such as: on a wall separating 
an unheated room; or in a draft from a stairwell, door, or window.
Do not locate in a damp area. This can lead to corrosion that will shorten 
thermostat life. 
Do not locate where air circulation is poor, such as: in a corner or an 
alcove; or behind an open door. 
Do not install the unit until all construction work and painting has been 
completed.
This thermostat does not require leveling.
You will need  #1 Phillips screwdriver (small) and
Drill with 3/16-in. (4.8mm) bit for this installation.
The 8022 can be used with most 24 volt gas, oil or electric heating and air conditioning systems, single-
stage heat pumps or gas millivolt heating systems. It cannot be used with 120 volt heating systems or 
multistage heat pumps. Ask The Home Depot for other thermostats to control those systems.
The 8022 is programmable. There are four programming periods 
per day. Each period can be programmed separately. 
You can use the built-in time/temperature programs, or alter them 
to suit your schedule. 
The 8022 separately programs Weekdays, Saturday, and Sunday 
- for both heating and cooling. 
You can easily override the programmed temperatures for as little 
as one programming period or for an entire vacation.
A large liquid crystal display shows time, day of the week, room 
and set temperatures. It will also remind you when the filter 
should be changed in your blower.
Temperature swing adjustment lets you fine-tune your system for maximum comfort and energy 
efficiency.
A 4-minute minimum off time in COOL protects your air conditioning system from being damaged.
Two "AA" batteries (not included) are used to retain your time and temperature programs, and to 
run the thermostat.
Caution
Switch electricity to the furnace and air conditioner OFF; 
then proceed with the following steps.
Remove cover from old thermostat. Most are snap-on types and simply pull 
off. Some have locking screws on the side or front. These must be loosened.   
Note the letters printed near the terminals. Attach labels (enclosed) to each 
wire for identification.
Label the wires one at a time.  You must have all the wires labeled before 
you proceed.
 With all wires labeled, remove them from the old unit.
Make sure the wires do not fall back inside the wall.  Wind them around a 
pencil to keep them from falling.
Loosen all screws on the old thermostat and 
remove it from the wall.
Fill wall opening with non-combustible insulation 
to prevent drafts. 
Separate front from back of unit. Press up on the 
catch on bottom of thermostat and swing the body 
away from the base, lift up to remove the body from 
the base. 
Hold the base against the wall, with the wires 
coming through the opening below the terminal block. 
Position the base for best appearance. If you chose to use the optional Wall 
Plate, put it in position before screwing base to wall.
Attach the base to the wall with the 
two screws provided.
If you are mounting the base to sheet 
rock or if you are using the old 
mounting holes, use the plastic 
anchors provided. Drill a 3/16-
in.(4.8mm) hole for the insert at each 
screw location, then mount the base.
When you have finished making connections. hook 
the top of the body onto the base, swing the body 
down, and snap the body onto the base.
Read instructions carefully before removing any wiring from existing thermostat. Wires must be labeled 
before they are removed. THERE IS NO STANDARD COLOR CODE. When removing wires from their 
terminals, ignore the color of the wires since these may not comply with the standard.
Note:
Note:
FOR ADVANCED USERS ONLY
FOR ADVANCED USERS ONLY
If you have an electric furnace system and the blower does 
not operate after installation, remove the thermostat, turn it 
over, and find the electric/gas heat selector jumper on the 
back of the control unit. Switch it to "Elect"(see Diag below).
1) The 8022 can run on batteries only.   (2AA Alkaline)   24VAC and MV
The batteries will last well over 1 year.  If the batteries are not replaced the 
thermostat will stop working.           Use the MV/C power jumper position.
2) The 8022 can run on the C wire if available.                  24VAC ONLY
As shown in the wiring diagrams, The C wire is the other side of the 24VAC 
heating transformer. If the C wire is used, the batteries are then for AC power 
loss only and will last much longer. The thermostat will continue working if the 
batteries die.              Use the MV/C power jumper position.
3) The 8022 can run on 24VAC series power.                         24VAC ONLY
Power for the thermostat comes from the W and RH wires. The batteries are 
then for AC power loss only and will last much longer.  The thermostat will 
continue working if the batteries die.  Use the FURN power jumper position.
To locate the Power Mode 
Jumpers. Remove the 
control unit from the wall 
mount, turn it over, and 
locate the jumper. It is set 
at the factory on MV/C. 
Change it from MV/C to 
FURN to use series 
power.
This option works with 
24VAC, .1 to 1 amp. 
systems only.  Verify 
operation. If it doesnt work 
go back to options 1 or 2 above.
5 Install Batteries
7 Power Options
8022 Features
6 Check Unit
6 Check Unit cont.
The 8022 requires batteries to operate 
your furnace and retain its programming in 
memory. 
Switch MODE switch to OFF and 
the FAN switch to AUTO.
Remove the front panel battery cover and 
install 2 AA alkaline batteries according to 
the polarity noted in the compartment.  
Initially, all LCD segments will go on. 
Press the RESET button to clear transient 
program memory.
NOTE: Replace the batteries when this LOW battery 
indicator appears on the display or once a year. When 
replacing batteries, you have approximately one minute before 
your custom program is lost.
Follow these procedures to verify you have correctly installed the unit.
To check HEAT mode:
Set the mode switch to HEAT. Set the fan 
switch AUTO.
Using the TEMP UP button raise the set point 
to 90deg allow the system 5 min to respond.  
Verify that heat is blowing from the system.
To check COOL mode:
Set the mode switch to COOL.
Press the TEMP DOWN button to a temp 5 
degrees below the room temperature.  
Allow the system 5 minutes to respond.
Verify that cool air is blowing from the system.
To check Fan: (If you connected the G wire - fan relay)
Switch the FAN switch to the ON position. Verify that air is blowing from 
the system. Return to AUTO position for normal operation.
C  RC O B
RH W Y G  
HEA
T           COOL
AUT
O        ON
OFF
FAN
C  RC O B
RH W Y G  
HEA
T           COOL
AUT
O        ON
OFF
FAN
Good
5ft.
(1.5m)
HEA
T           COOL
AUT
O        ON
OFF
DAY/CLOCK
SPECIAL
 DAY
FILTER
RETURN
HOLD
F.WARD
PROG.DA
Y
NEXT
RESET
B.W
ARD
FAN
AA
AA
HEA
T           COOL
AUT
O        ON
OFF
FAN
TEMP 
  UP  button
TEMP
DOWN  button
Set Temp 
Display
Mode 
Switch
Fan 
Switch
Congratulations, you have successfully installed your unit. Please 
proceed to the OPERATING Guide to initialize the new thermostat.
24
GAS  ELECT
12
o
C
o
C -
o
F
jumper
o
F
FURN
MV/C
12/24hr
jumper
Gas - Electric 
jumper
Circuit 
Board
Power Mode 
jumper
Rear View of control unit
HEA
T           COOL
AUT
O        ON
OFF
FAN
HEA
T           COOL
AUT
O        ON
OFF
FAN
PG
 1
PG
 2
PG
 3
PG
 4
PG
 5
PG
 6
PG
 7
PG
 8
PG
 9
PG
 10
PG
 16
PG
 12
Terminal 
Block
Thermostat
Base 
Wall 
Plate
Install guide 8022
4 Before you Connect Wires
Caution
D o   n o t   a l l o w   w i r e s   t o   t o u c h   e a c h   o t h e r   o r   p a r t s   o n   t h e r m o s t a t . 
W i r e s   mu s t   b e   ro u t e d   t h ro u g h   t h e   h o l e   i n   t h e   b a ck   p l a t e ,  b e l o w   t h e  
t e r m i n a l   b l o ck ,  o r   t h e y   w i l l   h i t   p a r t s   o n   t h e   c ov e r. 
Please follow these guidelines for safe and secure wire connections.
Determine which step-by-step wiring diagram you should use. Make sure your 
wires are labeled. This may require you to find the 'other end' connection for each 
wire on your heating or air conditioning equipment and read the label there.
     If you have a wire marked "C" its connection is optional. If you do connect it the 
thermostat will draw power from the C wire and this will extend battery life. 
Optional Wire Connections 
5 What Wires Do You Have?
Strip insulation 3/8 in. (9.5mm) from wire ends. 
Take care not to damage the labels for each wire in handling.
Connect labeled wires only to a terminal with corresponding letter.
Bend the wire slightly, insert the wire under the contact plate and 
tighten the screw down onto the wire.  
PG
 14
PG
 15
PG
 13
RH
G
Y
W
C
From Furnace
And AC unit
R
or
B
G
Y
R
C
From single stage 
heat pump
O
or
RC
G
Y
W
C
From Furnace
And AC unit
RH
Go To Page 13
Go To Page 14
Go To Page 12
RH
W
C
From Furnace
G
From Furnace
and AC unit
G
W
Y
RH
RC
C
R
G
Y
W
C
RH
or
From Furnace
and AC unit
PG
 11
PG
 12
STEP 1 - Connect the R (or RH) wire to 
the RH terminal on the thermostat. 
This connects the Heater Power to the 
thermostat.
STEP 2 - Connect the W wire to the W 
terminal on the thermostat.
This connects the heater control line to the thermostat.
Your Heater is now connected to the thermostat.
STEP 1 - Connect the R (or RH) wire 
to the RH terminal on the thermostat. 
This connects to the Heater Power .
STEP 2 - Connect the W wire to the 
W terminal on the thermostat.
This connects the heater control line 
to the thermostat.
STEP 3 - Connect the G wire to the G 
terminal on the thermostat.
This connects the Fan to the thermostat.
Your system is now connected to the thermostat.
Return To Page 7
Return To Page 7
STEP 1 - Connect the wire to the 
Y terminal on the thermostat. This 
connects to the Cooler compressor.
STEP 2 - Connect the RH or R wire 
to the RH terminal on the thermostat. 
This connects  the Heater/Cooler 
Power.
STEP 3 - Connect the W wire to the W terminal on the 
thermostat.  This connects to the heater control line.
STEP 4 - Connect the wire to the G terminal on the 
Thermostat.  This connects to the Fan.
Your HVAC system is now connected to the thermostat.
STEP 1 - Remove the orange 
Jumper wire.
STEP 2 - Connect the wire to 
the Y terminal on the thermostat. 
This connects to the Cooler 
compressor.
STEP 3 - Connect the RH wire to the RH 
terminal on the thermostat. This connects to the 
Heater Power .
STEP 4 - Connect the RC wire to the RC terminal on 
the thermostat. This connects to the Cooling Power .
STEP 5 - Connect the W wire to the W terminal on the thermostat.
This connects to the heater control line.
STEP 6 - Connect the wire to the G terminal on the Thermostat.
This connects to the Fan.
Your HVAC system is now connected to the thermostat.
Return To Page 7
STEP 1 - Connect the wire to the G 
terminal on the thermostat. 
This connects the Fan.
STEP 2 - Add a jumper wire between 
W and Y.
STEP 3 - Connect the Y wire to the 
terminal on the thermostat. 
This connects the Compressor.
STEP 4 - Connect the or B wire to the or B terminal 
on the thermostat. (If you have both O and contact 
Ritetemp or your local HVAC contractor for further help) 
This connects the change over valve.
STEP 5 - Connect the wire to the RC terminal on the Thermostat.  
This connects to the 24vac power.
Your HVAC system is now connected to the thermostat.
Return To Page 7
Return To Page 7
SINGLE STAGE 
HEAT PUMP 
5 WIRE 
4 WIRE 
2 WIRE Heating
(GAS MILLIVOLT or 24vac
NOTE: Wires marked with the dotted line are optional.
NOTE: Wires marked with the dotted line are optional.
NOTE: Wires marked with the dotted line are optional.
NOTE: Wires marked with the dotted line are optional.
NOTE: Wires marked with the dotted line are optional.
3 WIRE 
From Furnace
and AC unit
R
G
Y
C
O
or
B
W
RH
R
or
From Furnace
Go To Page 11
C
Go To Page 15
R  -  Single source power for heat/cool
       Note: R connects to both RC and RH using the Orange jumper
RH or 4 - HEATING POWER
RC - COOLING POWER
W -  HEATING CONTROL
G -  FAN RELAY  
C -  Common side of Heating Power
Y -  COMPRESSOR
O - DAMPER OR CHANGEOVER VALVE (POWERED IN COOL)
B -  DAMPER OR CHANGEOVER VALVE (POWERED IN HEAT)  
or R
FURNACE
jumper
wire
Heat 
Power
Heat
W
G
RH
C
FAN
Thermostat
HVAC SYSTEM
jumper
wire
 Heat 
Power
Heat
W
G
RH
C
FAN
Y
Cool
Comp
Thermostat
HVAC SYSTEM
Remove
jumper
wire
HEAT 
Power
Heat
W
G
RH
RC
C
FAN
Y
Cool
Comp
COOL 
Power
Thermostat
O  or  B
Single Stage HEAT PUMP 
Change
Over
G
O or B
R
C
FAN
Y
 
Comp
24VAC 
Power
jumper
wire
jumper
wire
Thermostat
jumper
wire
FURNACE
HEAT
Thermostat
R
W
C
HEAT 
Power
W
RH
R
or
From Furnace
C
RH
W
C
From Furnace
G
or R
B
G
W
Customer Support: 888-515-2585  or   Visit our website    www.ritetemp.biz