If you have configured your 6030 for 
heat pump control the MENU screen 
will display an additional icon - the 
HEAT PUMP ON/OFF icon.
     When using a heat pump with 
Auxiliary heat, if the heat pump 
cannot keep up and/or is defective, 
touch the 
MENU button, then touch 
PUMP ON; the PUMP OFF icon will 
come on. The aux heat will then be 
your only source of heat.  
   When the heat pump is again operational, be sure to turn 
the heat pump back on by touching 
MENU and then PUMP 
OFF (off icon goes out) as the aux heat is more expensive 
than pump heat.
Heat Pump Features
     This thermostat can be used with all millivolt and 24VAC heating and cooling systems. 
It cannot be used with line voltage systems. This thermostat is digital and your desired 
heat or cool temperatures can be easily be set on the large touch screen with the 
UP/DOWN arrows.  A minimum 4 minute off time protects heating and cooling systems 
from damage. 
     
This thermostat uses a new 
technique called sequential 
staging for more comfort with 
faster reaction to requested 
temperature changes. 
     