Bock Water heaters 80PDVI-250-NA-A Leaflet

Page of 2
www.bockwaterheaters.com 
110 South Dickinson Street , Madison, Wisconsin 53703 
Toll Free 800.794.2491
Phone 608.257.2225
Fax 608.257.5304
80029 Rev 6/08
Natural Gas use the suffix "NA", Example: 80PDVI-150-NA
LP on 80PDVI-250 and 100PDVI-250 only. Use suffix "XA" to order. Example: 80PDVI-150-XA
ASME Construction available on the 80PDVI-250 and 100PDVI-250 only; Use suffix "A" to order; Example: 80PDVI-250-NA-A
For Low NOx compliance to meet SCAQMD requirements, place an "LN" in the model number; Example: 80PDVILN-250-NA
T=Top, F=Front, R=Rear
These models meet or exceed the Thermal Efficiency and Standby Loss Requirements of ASHRAE 90.1b current standard.
115V A.C. Required
T&P Valve, Brass Drain Valve, Dielectric Fittings, Magnesium Anode Rods: Factory Installed
Pressures (all): Working Pressure, 150 psi;  Tested Pressure, 300 psi
Warning:  Installation should be in accordance with all national and/or local codes.  In the absence of local codes, refer to NFPA 54 or ANSI Z21.10.1.
Caution:  The recommended maximum hot water termperature setting for normal residential use is 120°F.  Bock recommends a tempering valve or anti-scald 
valve be installed and used according to the manufacturer’s directions to prevent scalding.
Energy Saver
P
ower 
D
irect 
V
ent
I
ndependent Vent System
Gas Water Heaters
This product is available from:
MODEL 
NUMBER
STORAGE 
(GAL)
RATED
INPUT 
(BTU/HR)
1ST HR 
DEL GAL 
@ 100
° F 
RISE
RECOVERY GPH 
@ DEGREE RISE
DIMENSIONS (INCHES)
SHIPPING WEIGHT
HEIGHT
DIA.
TOP 
WATER 
CONN.
F&R 
HOT 
CONN.
F&R 
COLD 
CONN.
GAS 
CONN.
TOP 
VENT 
HEIGHT
WATER 
CONN.
GAS 
CONN. 
DIA.
RELIEF 
VALVE 
OPEN.
STD 
(LBS)
ASME 
(LBS)
40
° F 100° F 140° F
  80PDVI-150
80
150,000
204
364
145
104
63-1/2
28-1/4
65-1/8
51-5/16 20-3/16 17-1/4
68-3/16
1-1/12(T&F) 
2(R)
3/4
3/4
645
N/A
  80PDVI-200
80
199,999
253
485
194
139
63-1/2
28-1/4
65-1/8
51-5/16 20-3/16 17-1/4
68-3/16
1-1/12(T&F) 
2(R)
3/4
3/4
645
N/A
  80PDVI-250
83
250,000
301
606
242
173
63-1/2
28-1/4
65-1/8
51-5/16 20-3/16 17-1/4
73-1/16
1-1/12(T&F) 
2(R)
3/4
1
645
720
  100PDVI-150
100
150,000
219
364
145
104
74-1/8
28-1/4
74-1/8
60-5/16 20-11/16 17-1/4
77-3/16
1-1/12(T&F) 
2(R)
3/4
3/4
735
N/A
  100PDVI-200
100
199,999
266
485
194
139
74-1/8
28-1/4
74-1/8
60-5/16 20-11/16 17-1/4
77-3/16
1-1/12(T&F) 
2(R)
3/4
3/4
735
N/A
  100-PDVI-250
100
250,000
312
606
242
173
74-1/8
28-1/4
74-1/8
60-5/16 20-11/16 17-1/4
82-1/16
1-1/12(T&F) 
2(R)
3/4
1
735
815
 Propane Gas Inputs (LP)
1ST HR. 
DEL GAL. 
@ 100° F 
RISE
RECOVERY GPH @ 
DEGREE RISE
40° F
100° F
140° F
 80PDVI-250-XA  225,000 BTUH
274
545
218
156
 100PDVI-250-XA  225,000 BTUH
288
545
218
156
 (LN) LowNOx Burners
1ST HR. 
DEL GAL. 
@ 100° F 
RISE
RECOVERY GPH @ 
DEGREE RISE
40° F
100° F
140° F
 80PDVILN-150
150,000 BTUH
201
364
145
104
 80PDVILN-200
180,000 BTUH
250
436
175
125
 80PDVILN-250
220,000 BTUH
298
533
213
152
 100PDVILN-150 150,000 BTUH
215
364
145
104
 100PDVILN-200 180,000 BTUH
245
436
175
125
 100PDVILN-250 220,000 BTUH
283
533
213
152
A
C
G
D
E
B
F