Brother S-7200C User Manual

Page of 172
 
 
    S-7200C
 
5. FUNCTION SETTINGS (G10 OPERATION PANEL)
52
[If set to level 3] 
To make individual settings, select level 3.   
Confirm the protection level
 
 
 
 
 
 
 
 
Select an individual setting number (1-6) 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Individual 
setting number 
Details of main operation disabled 
1 MAX 
key 
2 Function 
setting 
None (setting disabled) 
Mainly keys with indicators 
Stitch number settings (ABCD) 
6 Initialization 
Make the individual protection (ON/OFF) setting
 
 
Confirm the protection setting value
 
 
 
 
 
 
Use the 
  key to turn the setting on, and use the 
 key to turn
the setting off.   
* If the individual protection setting value is different from the
original value, the protection setting value will flash. 
 
 
The protection setting value will return to illuminating steadily. 
 
Protect setting mode will be exited and normal operation will be possible.
 
NOTE:
The range for disabling operation varies depending on the
setting for DIP switch 1. 
For details, refer to <Protection setting list> (P.53).
 
 
 4206M 
 
Individual setting 
number
 
Individual protection setting value ([-]:OFF、[
]:ON)
 
 2076B  4161M
 2078B 
 2100B  2138M  2139M 
 2077B 
 
* When the 
 
 
key is pressed, the display will return to the
protection level setting display [PLV      3].
 
 
NOTE: