Haier 3150 SB User Manual

Page of 40
Model 3150 
38
310622L
Model 3150
Performance Chart
Test Conditions: Pump tested in water with inlet submerged
To find Fluid Outlet Pressure
(psi/MPa/bar) at a specific fluid flow (gpm/lpm) and 
operating air pressure (psi/MPa/bar):
1. Locate fluid flow rate along bottom of chart.
2. Follow vertical line up to intersection with selected 
fluid outlet pressure curve.
3.Follow left to scale to read fluid outlet pressure.
To find Pump Air Pressure
(scfm or m
3
/min) at a specific fluid flow (gpm/lpm) and 
operating air pressure (psi/MPa/bar):
1. Locate fluid flow rate along bottom of chart.
2. Read vertical line up to intersection with selected air 
consumption curve.
3. Follow left to scale to read fluid outlet pressure.
3150 3A Performance Chart
150
(4.2)
125
(3.5)
100
(2.8)
75
(2.1)
50
(1.4)
25
(0.7)
0
0
20
(76)
40
(152)
60
(227)
80
(303)
100
(379)
120
(454)
140
(531)
160
(606)
20
(1.4, 0.14)
40
(2.8, 0.28)
60
(4.2, 0.42)
80
(5.5, 0.55)
100
(7, 0.7)
120
(8.4, 0.84)
Air
 Co
ns
um
p
tio
scfm (
m
3
/min)
F
luid
 O
u
tlet
 Pr
es
su
re
psi (bar
, MP
a)
TI8644a
TI8645a
Fluid Flow
gpm (lpm)