Haier 3150 SB User Manual

Page of 40
Installation
310622L
5
Installation
General Information
The typical installation shown in F
. 3 is only a 
guide for selecting and installing system compo-
nents. Contact your Graco distributor for assistance 
in planning a system to suit your needs.
Always use genuine Graco parts and accessories.
Reference numbers and letters in parentheses refer 
to the callouts in the figures and the parts lists on 
pages 26 - 31.
Leak Detection System
Tighten Clamps Before First Use
After you unpack the pump, and before you use it for the 
first time, check all clamps, and tighten as necessary.
Stand
1.
Place the stand assembly on a level surface.
2.
Mount the pump securely to the brackets using bolts 
(659).
3.
Tighten the bolts (V) to hold the slotted bracket in 
place. See F
F
IG
. 1
Grounding
To reduce the risk of static sparking, ground the pump 
and all other equipment used or located in the pumping 
area. Check your local electrical code for detailed 
grounding instructions for your area and type of equip-
ment.
Pump: Connect a ground wire and clamp as shown 
in F
. 2. Loosen the grounding screw (W). Insert 
one end of a 12 ga (1.5 mm²) minimum ground wire 
(X) behind the grounding screw and tighten the 
screw securely. Connect the clamp end of the 
ground wire to a true earth ground. To order a 
ground wire and clamp, order part number 222011.
The pump is very heavy (see Technical Data on 
pages 34 and 37 for specific weights). If the pump 
must be moved, follow the Pressure Relief Proce-
dure
 on page 10 and have two people lift the pump 
by grasping the outlet manifold securely, or use 
appropriate lifting equipment. Never have one person 
move or lift the pump.
A leak detection system will be included with all 
 approved pumps. See manual 311200 
included with leak detector for leak detector instal-
lation instructions.
See pages 30 and 31 for parts.
Bolts (V) must be tightened to hold the bracket in 
place during operation.
Moving Parts Hazard
Keep clear of moving parts.
Bolts (V) may be loosened to allow the pump, while 
still securely mounted to the bracket, to be rotated 
for draining or servicing.
TI8765a
659
V