Honeywell DC6 User Manual

Page of 46
23 
11.  Troubleshooting 
 
Difficulty 
Probable Cause 
Remedy 
 
 
 
Faulty power source. 
Check power source. 
Blown fuse, circuit breaker. 
Replace - eliminate overload. 
Broken wire. 
Locate and repair. 
Wired improperly. 
Check diagram. 
Pump does not start 
Process piping blockage. 
Open valves, clear other obstructions. 
Motor not running. 
Check power source.  Check wiring 
diagram (see above). 
Supply tank empty. 
Fill tank. 
Lines clogged. 
Clean and flush. 
Closed line valves. 
Open valves. 
Ball check valves held open with solids.  Clean – inspect, flush with clear fluid. 
Vapor lock, cavitation. 
Increase suction pressure. 
Prime lost. 
Re-prime, check for leak. 
Strainer clogged. 
Remove and clean.  Replace screen if 
necessary. 
No delivery 
Stroke adjustment set at zero. 
Increase stroke length setting. 
Motor speed too low 
Check voltages, frequency, wiring, and 
terminal connections.  Check nameplate 
vs. Specifications. 
Check valves worn or dirty 
Clean, replace if damaged 
Calibration system error 
Evaluate and correct 
Product viscosity too high 
Lower viscosity by increasing product 
temperature or dilution.  Increase pump 
and/or piping size 
Low delivery 
Product cavitating 
Increase suction pressure.  
Check valve leakage. 
Clean, replace if damaged. 
Leak in suction line. 
Locate and correct. 
Strainer fouled. 
Clean or replace screen. 
Product change. 
Check viscosity and other variables. 
Delivery gradually 
drops. 
Supply tank vent plugged. 
Unplug vent. 
Leak in suction line. 
Locate and correct. 
Product cavitating. 
Increase suction pressure. 
Entrained air or gas in product. 
Consult factory for suggested venting. 
Motor speed erratic. 
Check voltage and frequency. 
Delivery erratic. 
Fouled check valves. 
Clean, replace if necessary. 
 
Inadequate backpressure 
Increase discharge pressure to obtain a 
minimum pressure difference of 5 pis 
from suction to discharge 
Suction pressure higher than discharge 
pressure. 
Install backpressure valve or consult 
factory for piping recommendations. 
Back pressure valve set too low. 
Increase setting. 
Back pressure valve leaks. 
Repair, clean, or replace. 
Delivery higher than 
rated.