Hearth & Home Technologies 21M-ACC User Manual

Page of 44
Page  2
7039-131F
September 1, 2008
R
2100 Millennium Wood Stove  (ACC)
Hearth & Home Technologies welcomes you to our tradi-
tion of excellence!  In choosing a Quadra-Fire appliance, 
you have our assurance of commitment to quality, durabil-
ity, and performance.
This commitment begins with our research of the market, 
including ‘Voice of the Customer’ contacts, ensuring we 
make products that will satisfy your needs. Our Research 
and Development facility then employs the world’s most 
advanced technology to achieve the optimum operation of 
our stoves, inserts and fireplaces.  And yet we are old-fash-
ioned when it comes to craftsmanship.  Each unit is meticu-
lously fabricated and surfaces are hand-finished for lasting 
beauty and enjoyment.  Our pledge to quality is completed 
as each model undergoes a quality control inspection.  
We wish you and your family many years of enjoyment in the 
warmth and comfort of your hearth appliance.  Thank you for 
choosing Quadra-Fire.
and Welcome to the Quadra-Fire Family
!
SPÉCIFICATIONS DE LA VENTILATION:
MUR SIMPLE: De six (6 inches) (152mm) de diamètre le connecteur de conduit de 
minimum d'acier noir ou bleu de minimum de 24MSG, avec une cheminée bâtit en 
usine UL103HT* de Classe "A", adéquate pour usage avec les combustions solides, 
ou une cheminée de briques, avec espaces libres référés.
MUR  DOUBLE:  De  six  (6  inches)  (152mm)  de  diamètre,  le  connecteur  du  conduit 
d'air isolé pour mur double avec une cheminée bâtit en usine UL103HT* de Classe 
"A, ou une cheminée de briques, avec espaces libres alloués.
MAISON  MOBILE:    Utiliser  un  conduit  de  mur  double  par  Dura-Vent  DVL,  Selkirk 
Metalbestos  DS  ou  Security  DL.  Doit  être  équipé  d'un  arrêt  d'étincelle.  Utiliser  les 
espaces libres pour mur double comme mentionné ci-bas.
MINIMUM CLEARANCES TO COMBUSTIBLES  In Inches & (Millimeters)
NOTE:  All "A" , "C" and "F" Dimensions are to inside diameter of the flue collar.
LISTED ROOM HEATER, SOLID FUEL TYPE.   
ALSO FOR USE IN MOBILE HOMES.  (UM) 84 HUD .
"For Use with Solid Wood Fuel Only" 
1445 N. Highway, Colville, WA 99114
www.quadrafire.com
Install  and  use  only  in  accordance  with 
manufacturer's  installation  and  operating 
instructions.  Contact local building or fire officials 
about  restrictions  and  installation  inspections  in 
your  area.  Do  not  obstruct  the  space  beneath 
heater.
WARNING - For Mobile Homes:  Do not install in 
a sleeping room.  An outside combustion air inlet 
must be provided and unrestricted while unit is in 
use.    The  structural  integrity  of  the  mobile  home 
floor,  ceiling  and  walls  must  be  maintained.   The 
stove needs to be properly grounded to the frame 
of  the  mobile  home.    Components  required  for 
mobile  home  installation:    Outside  Air  Kit,  Part 
Number 831-1780.
Refer  to  manufacturer's  instructions  and  local 
codes  for  precautions  required  for  passing 
chimney through a combustible wall or ceiling and 
maximum offsets.
Inspect  and  clean  chimney  frequently  -  Under 
Certain Conditions of Use, Creosote Buildup May 
Occur Rapidly.
Do  not  connect  this  unit  to  a  chimney  serving 
another appliance.
Optional  Components:    Optional  Blower,  Part 
831-1701.
Electrical Rating:  115 VAC, 1.2 Amps, 60 Hz.
Route  power  cord  away  from  unit.    Do  not  route 
cord under or in front of appliance.
DANGER: Risk of electrical shock.  Disconnect 
power supply before servicing.
Replace  glass  only  with  5mm  ceramic  available 
from your dealer.
Do not use grate or elevate fire.  Build wood fire 
directly on hearth.
Do  not  overfire  -  if  heater  or  chimney  connector 
glows, you are overfiring.
Operate  only  with  the  fuel  loading  door  closed.  
Open only to add fuel to the fire.
CAUTION
:
U.S. ENVIRONMENTAL PROTECTION AGENCY - Certified to 
comply with July 1990 particulate emission standards.
2008  2009  2010  Jan.  Feb.  Mar.  Apr.  May  June July  Aug. Sept. Oct.  Nov.  Dec.
PREVENT HOUSE FIRES
FLOOR PROTECTION
:
Floor  protector  must  be  a  3/8  inch  min.  thickness, 
non-combustible  material  or  equivalent,  extending 
beneath heater and to front/sides/rear as indicated 
on the diagram below. 
Exception: Non-combustible 
floor protections must extend beneath the flue pipe 
when installed with horizontal venting and extend 2 
inches  (51mm) beyond each side.  
Report / Rapport
061-S-70-6
TESTED TO:/ TESTÉ À:
   UL 1482,  ULC S627-00. 
Manufactured by:
HOT  WHILE  IN  OPERATION  DO  NOT  TOUCH,  KEEP  CHILDREN AND  CLOTHING AWAY.  CONTACT  MAY  CAUSE  SKIN  BURNS.    KEEP 
FURNISHINGS AND OTHER COMBUSTIBLE MATERIAL FAR AWAY FROM THE APPLIANCE. SEE NAMEPLATE AND INSTRUCTIONS
SINGLE WALL PIPE 
15 (381)  11 (279)  21.5 (546)  13 (330)  8.5 (216)  17 (432)  56 (1422) 
N/A
DOUBLE WALL PIPE 
8.75 (222)  5.75 (146)  20 (508)  10.5 (267)  7.5 (191)  16 (406)  43 (1092) 
N/A
SINGLE WALL PIPE     
  14 (356)  10 (254)  20.5 (521)  12 (305)  8.5 (216)  17 (432)  56 (1422)  9.5 (241)
DOUBLE WALL PIPE 
9.5 (241)  5.5 (140)  21.5 (546)  13 (330)  7.5 (191)  16 (406)  43 (1092)  5 (127)
INSTALLATION: ALCOVE - Six inch (6 inches) (152mm) diameter listed DOUBLE WALL air insulated connector pipe with UL 103 HT listed factory-built 
Class "A" chimney, or a masonry chimney. (Mobile Home must be equipped with a spark arrestor.) Maximum depth of Alcove shall be no more than 48 
inches (1220mm) with a minimum height of 43 inches (1092mm) to top of unit, and the referenced clearances.
DOUBLE WALL PIPE 
     9.5 (241)   5.5 (140)  21.5 (572)  13.5 (343) 
N/A 
N/A          43 (1092)    5 (127)
VENT SPECIFICATIONS:
SINGLE  WALL: Six  inch  (6  inches)  (152mm)  diameter,  minimum  24  MSG  black  or 
blued  steel  connector  pipe,  with  a  listed  factory-built  UL103HT*  Class  "A"  chimney, 
suitable for use with solid fuels, or a masonry chimney, and the referenced clearances.
DOUBLE  WALL: Six  inch  (6  inches)  (152mm)  diameter,  listed  double  wall  air 
insulated connector pipe with listed factory-built UL103HT* Class "A" chimney, or  a 
masonry chimney and the referenced clearances
*In Canada must comply with Standard CAN/ULC-S629-M87 for the 650 degree 
Factory-built chimneys.
MOBILE HOME:  Use double wall pipe by Dura-Vent DVL, Selkirk Metalbestos DS or 
Security  DL  double  wall  connector  pipe.  Must  be  equipped  with  a  spark  arrestor.  
Apply double wall clearances below when installing unit.
SERIAL NO. / NUMÉRO DE SÉRIE
2100 Millennium ACC
A
B
C
D
E
F
E
F
G
H
G
A
B
C
D
R
7039-134
CHAUD LORS DE L'OPÉRATION. NE PAS TOUCHER. GARDEZ LES ENFANTS ET LES VÊTEMENTS LOIN DE L'ESPACE DÉSIGNÉ DE L'INSTALLATION. LE CONTACT PEUT CAUSER DES 
BRÛLURES À LA PEAU. GARDEZ LES MEUBLES ET LES MATÉRIAUX COMBUSTIBLES LOIN DE L'ESPACE DÉSIGNÉ DE L'APPAREIL. VOIR L'ÉTIQUETTE ET LES INSTRUCTIONS.
ATTENTION:
APPAREIL DE CHAUFFAGE DE PIÈCE, DE TYPE DE 
COMBUSTIBLE SOLIDE, POUR USAGE DANS LES 
MAISONS MOBILES. (UM) 84-64 HUD. "Pour Usage 
Avec Bois Solide Seulement"
Installez  et  utilisez  en  accord  avec  les  instructions 
d'installation et d'opération du fabricant. Contactez le bureau 
de la construction ou le bureau des incendies au sujet des 
restrictions  et  des  inspections  d'installation  dans  votre 
voisinage. Ne pas obstruez l'espace en dessous de l'appareil.
AVIS - Pour Les Maisons Mobiles:  Ne pas installer dans une 
chambre à coucher. Un tuyau extérieur de combustion d'air 
doit être installé et ne doit pas être obstrué lorsque l'appareil 
est en usage. La structure intégrale du plancher, du plafond et 
des  murs  de  la  maison  mobile  doit  être  maintenue  intacte. 
L'appareil  de  chauffage  doit  être  fixé  à  la  charpente  de  la 
maison mobile. Les composants requis pour l'installation des 
maisons  mobiles: Assemblage  d'air  extérieur,  Numéro  de 
Pièce 831-1780.
Référez  vous  aux  instructions  du  fabricant  et  des  codes 
locaux  pour  les  précautions  requises  pour  passer  une 
cheminée à travers un mur ou un plafond combustibles, et les 
compensations maximums.
Inspectez  et  nettoyez  la  cheminée  fréquemment.  Sous 
certaines  conditions,  il  se  peut  que  la  créosote  s'accumule 
rapidement.
Ne  pas  connecter  cet  appareil  à  une  cheminée  servant  un 
autre appareil.
Composants  Optionnels:  Ventilateur  Optionnel,  Pièce 
#831-1701.
Puissance Électrique: 115 VAC, 1.2 Amps, 60 Hz.
Éloignez le fil électrique de l'appareil. Ne pas faire passer le fil 
électrique au dessus ou en dessous de l'appareil.
DANGER: Il y a risque de décharge électrique.  Déconnectez 
le fil électrique de la prise de contact avant le service.
Remplacez la vitre seulement avec une vitre céramique de 5 
mm disponible chez votre fournisseur.
N'élevez pas le feu. Bâtissez le feu de bois directement sur 
l'âtre.
Ne pas surchauffer. Si l'appareil de chauffage ou le tuyau de 
cheminée rougissent, vous surchauffez.
Opérez l'appareil seulement lorsque la porte de chargement 
est  fermée.  Ouvrez  la  porte  seulement  lorsque  vous  devez 
ajouter des combustibles dans le feu.
PRÉVENTION DES FEUX DE MAISON
PROTECTION DU PLANCHER
:
Le protecteur de plancher doit être d'un minimum de 3/8 inch 
d'épaisseur,  de  matériel  incombustible  ou  équivalent, 
s'étendant du dessous de l'appareil de chauffage à l'avant, 
aux  cotés  et  à  l'arrière  comme  indiqué  sur  le  diagramme 
suivant.  Exception:  Les  protections  incombustibles  du 
plancher  doivent  s'étendre  en  dessous  du  conduit  de 
cheminée lorsqu'installées avec une ventilation à l'horizontale 
et s'étendre de 2 inches (51mm) de chaque côté.
ESPACES LIBRES MINIMUM DES MATÉRIAUX COMBUSTIBLES En Pouces & 
(millimètres)
NOTE:  Toutes les dimensions "A", "C", et "F" sont à partir du diamètre intérieur de 
l'entrée du conduit.
BACKWALL/SIDEWALL
MUR ARRIÈRE/MUR DE CÔTÉ 
STOVE TO CEILING CLEARANCE
ESPACE LIBRE DU POÊLE AU PLAFOND
CORNER INSTALLATION
INSTALLATION DU COIN 
ALCOVE TOP VIEW /
VUE DU HAUT DE L'ALCÔVE 
ALCOVE SIDE VIEW / 
VUE DE CÔTÉ DE L'ALCÔVE
CONDUIT DU MUR SIMPLE
CONDUIT DU MUR SIMPLE
C
ONDUIT DU MUR DOUBLE
CONDUIT DU MUR DOUBLE
INSTALLATION: FULL VERTICAL / ENTIÈREMENT VERTICALE  
INSTALLATION: HORIZONTAL WITH MINIMUM 2 FT VERTICAL OFF STOVE TOP
INSTALLATION: HORIZONTALE AVEC 609mm VERTICAL MINIMUM DU HAUT DU POÊLE
INSTALLATION: ALCÔVE - De six (6 inches) (152mm) de diamètre, le connecteur du conduit d'air isolé pour mur double avec une cheminée bâtit en usine 103HT de Classe "A", ou une 
cheminée de briques. (Les maisons mobiles doivent être équipées d'un arrêt d'étincelle). La profondeur maximum de l'alcôve ne doit pas être de plus de 48 inches (1220mm) avec une 
hauteur minimum de 43 inches (1092mm) du haut de l'appareil, et des espaces libres alloués. 
CONDUIT DU MUR DOUBLE
DO NOT REMOVE THIS LABEL / NE PAS ENLEVER L'ÉTIQUETTE
Made in U.S.A./Fait Aux États-Unis
*Au Canada doit conformer a CAN/ULC-S629-M87 la norme pour 650 degré C cheminée 
bâtit en usine.
Fabriqué par:
007004
16" from glass
8 in.
USA
Fuel loading door
5-3/4 in. 2-1/4 in."
29-5/8 in.
minimum
36 in.
minimum
CANADA
203mm (8 in.)
203mm
(8 in.)
203mm
(8 in.)
457mm (18 in.)
1168mm 
(46 in.)
minimum
1078mm (42-7/16 in.)
minimum
O-T L
Tested and 
Listed by
Portland
Oregon USA
OMNI-Test Laboratories, Inc.
C
US
SAMPLE OF SERIAL NUMBER / SAFETY LABEL
LOCATION:  BACK OF APPLIANCE
Serial No.
Model 
Name
Test Lab & 
Report No.
Mfg. Date
S A
M P
L E