Hearth & Home Technologies 21M-ACC User Manual

Page of 44
Page  22
7039-131F
September 1, 2008
R
2100 Millennium Wood Stove  (ACC)
F.  Burn Rates and Operating Efficiency
For maximum operating efficiency 
1.  This appliance has a timer system (ACC) that operates 
the stove at its maximum efficiency removing any guess 
work for the homeowner.  Follow the instructions below 
for each burn rate for the Start-Up Air Control and Burn 
Rate Air Control.  
Figure 22.1.
2.  Burn dry, well-seasoned wood.
Burn Rates
1.  Starting a Fire and Reloading
Open  both  controls  fully  by  raising  the  Burn  Rate Air 
Control all the way up until it stops and slide the Start-up 
Air Control back until it stops.  After loading the stove with 
wood  and starting the fire, set both controls to the desired 
setting by following the burn rate instructions below.  
2.  High Burn Rate - Maximum Heat
Raise the Burn Rate Air Control all the way up until it stops 
(top marker) to a fully open position.  Slide the Start-Up Air 
Control all the way back until it stops (HI marker) and leave 
it there. This setting over-rides the timer system (ACC) so 
you must monitor the fire closely while in this setting.
3.  Medium-High Burn Rate
 -
 15,000 to 30,000 BTU/hr
Raise the Burn Rate Air Control all the way up until it 
stops (top marker) to a fully open position.  Slide the 
Start-Up Air Control all the way back until it stops (HI 
marker) and then pull forward until it stops.  This activates 
the timer system (ACC).
2.  Burn Rate Air Control
This air supply enters at the upper front of the firebox, near the 
top of the glass door.  This preheated air supplies the neces-
sary fresh oxygen to mix with the unburned gases, helping 
to create second, third and fourth combustions.  This air is 
regulated by the Burn Rate Air Control.  There are four settings 
High, Medium-High, Medium-Low and Low.  When the control 
is raised all the way up it is on the High setting and when 
pushed all the down it is on the Low setting. 
Figure 22.1.
NOTE:  These are approximate settings, and will vary with 
type  of  wood  or  chimney  draft.  Due  to  altitude  and  other 
environmental circumstances, this operational information is 
a guideline only.  
WARNING
Risk of Fire.
When set on High Burn Rate and over-riding 
the Automatic Combustion Control system an 
overfire situation can occur and may result in a 
chimney fire.
Overfiring will void the stove warranty.
4.  Medium-Low Burn Rate - 10,000 to 15,000 BTU/hr
Raise the Burn Rate Air Control up to the bottom of 
the middle marker and stop.  Slide the Start-Up Air 
Control all the way back until it stops (HI marker) and 
then pull forward until it stops.  This activates the timer  
system (ACC).
5.  Low Burn Rate - Below 10,000 BTU/hr
Leave the Burn Rate Air Control at the bottom marker. 
Slide the Start-Up Air Control all the way back until it 
stops (HI marker) and then pull forward until it stops.  
This activates the timer system (ACC).
F
igure 22.1  
NOTE:  
Operate appliance on High Burn 15 minutes a 
day to help keep flue/chimney clean.
START-UP 
REAR AIR 
HI 
Closed 
Wide 
Open 
“HI” setting 
over-rides 
Timer 
After activating the timer (ACC), if the control is placed 
within the rear air section on the label it will allow rear air 
to enter the firebox.  This will not interfere with the timer 
gradually closing the front air channel in 25 minutes.  If 
control is set on “HI” it over-rides the timer (ACC).
High (Open) 
Low (Closed) 
Start-Up Air 
Control 
Burn Rate 
Air Control 
Front Air Channel  
Operated by Timer 
Rear Air Channel 
Operates independently 
from Timer 
 
HIGH 
LOW 
Timer 
Timer  Manual 
Shut-off 
Shown with Side 
Shield Removed