15 
 
 
I
NSTALLING 
I
A M
OBILE 
H
OME 
 
 
Follow these special requirements for installing your 
stove in a mobile home.   
 
• 
Install the stove in accordance with 24 CFR, Part 
3280 (HUD) 
• 
You must use the Tribute outside air kit Assembly 
390-53400 
• 
Ensure that the outside air inlet must remain clear of 
any objects, leaves, icing, snow, or other debris. Keep 
the inlet away from any exhaust fans. The inlet 
requires an adequate amount of ventilation. If the 
inlet becomes restricted during operation,  the unit 
may starve for room air, which may cause smoke 
spillage and an inability to maintain a proper fire. 
This smoke may set off any smoke detectors if 
installed.  
• 
Permanently attach the stove to your mobile home’s 
floor.  Use 1/4" holes in each leg base to bolt down 
the stove.  
• 
Install one of the following Dura-Vent Mobile Home 
Chimney & Connector Kits: 
 
 
6DP-MH 6” Diameter S/N 9096N 
 
7DP-MH 7” Diameter S/N 9196N 
 
8DP-MH 8” Diameter S/N 9296N 
 
        Each kit includes: 
    
Stainless spark arrester cap, storm collar,  
 
Adjustable vented flashing – 0/12 – 6/12, 
 
Two 24” Dura/Plus* chimney pipes, 24” 
support box with built-in starter section and 
trim. 
         * (UL or ULC approved equipment is acceptable) 
 
 
• 
Chimney must be removed when transporting Mobile 
Home. 
• 
Use silicone to create an effective vapor barrier at the 
location where the chimney or other component 
penetrates to the exterior of the structure. 
 
 
 
¦   WARNING: 
DO NOT INSTALL IN A SLEEPING ROOM 
 
 
 
¦  
CAUTION:
 
MAINTAIN THE STRUCTURAL INTEGRITY 
OF THE MOBILE HOME
 
WALLS, FLOOR,
 
CEILING, AND ROOF WHILE YOUR STOVE 
IS INSTALLED AND IN USE
. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Typical Mobile Home installation.  
Support Box
with built-in
starter section
Chimney supported by ceiling.
Chimney Cap
Storm Collar
Flashing
Adjustable Roof
Stovepipe
Chimney 
Chimney Section