WaTer sOfTener DisinfeCTiOn
The  materials  of  construction  of  your  water  softener  will  not 
support bacterial growth nor will these materials contaminate 
a water supply. However, the normal conditions existing dur-
ing shipping, storage, and installation indicate the advisability 
of disinfecting a softener after installation, before the softener 
is used to treat potable water. In addition, during normal use 
a softener may become fouled with organic matter or in some 
cases, with bacteria from the water supply.
 
Therefore, every water softener should be disinfected after 
installation, some will require periodic disinfection during their 
normal life. Disinfect as follows:
SODIUM HYPOCHLORITE (household bleach)
5.25%  SODIUM  HYPOCHLORITE  solutions  are  available 
under such trade names such as Clorox, Linco, Bo Peep, 
White Sail and Eagle Brand Bleach. If stronger solutions are 
used, such as those sold for commercial laundries, adjust 
the dosage accordingly.
    1. Dosage:
      a. Softening  resin;  1.2  fluid  ounce  per  cubic  foot  of  
        mineral (see page 33).
    2. Add the required amount of hypochlorite solution to the  
      brine well of the brine tank.
      a. Proceed with the normal regeneration.  Press regen  
        and allow the water softener to go through a normal  
        regeneration.
1.   Salt Usage: See your water conditioning professional for a rec-
ommendation on the best type of salt for your application.
2.  Brine Tank Cleaning:
  a.  Remove brine tank cover.
  b.  Scoop out as much old salt as possible.
  c.  Disconnect brine tubing from safety brine valve at brine well.
  d.  Remove safety brine valve from brine well.
  e.  Place one hand in brine well to hold overflow nut and  
 
remove 2 piece overflow.
f.  Remove optional brine well and grid plate, if used, from  
 
brine tank.
g.  Remove any remaining salt and/or impurities from brine tank.
h.  Using clean water and a brush or rag, wipe and rinse inside  
 
of brine tank.  Also wipe and rinse the grid plate and brine well.
i.  Reassemble brine tank reversing steps c - f.  Note: If grid  
 
plate  is  used  and  it  is  damaged  or  cracked,  replace  with  
 
new one.
j.   Put brine tank in place making sure there is no debris or  
 
foreign material beneath it.
k.  Reconnect brine tubing to safety brine valve.
l.  Manually add 6 inches of water to the brine tank (or to  
 
approximately 1” above the grid plate, if used).
m.   Add new salt.  Important:  Do not add the old salt which  
 
was  removed  earlier  unless  it  is  clean  and  not  mushy.   
 
We recommend using new salt.
n.  Follow the disinfection instructions found at the top of this  
 
page.
o.   Put on brine tank cover. 
MisCellaneOus
In cold weather climates it is common for plumbing systems that are 
not in use to be “winterized“ or drained of all water to prevent any 
damage that may be caused by the excessive expansion of water 
when it freezes. To prevent damage to a water softener it must be 
properly drained also. A simple way to properly drain or winterize 
a water softener is to use compressed air to force all of the water 
out of the softener mineral tank. The following procedure will explain 
the process:
1)  Initiate the softener into a manual regeneration cycle.  Advance 
control to backwash and allow it to complete the backwash cycle 
(this will clean the media) and start into the brine-draw cycle. 
Note: Be sure there is salt in the brine tank and water has been 
in contact with salt at least 20 minutes.  Allow the regeneration 
to continue in the brine draw cycle until the brine is drawn out 
of the salt keeper and the air check at the bottom of the brine 
pick-up tube shuts off. At this time no more brine is introduced 
into the softener and the slow rinse process begins.
2)  Turn the water supply inlet and outlet valves off to the water 
softener as soon as the air check shuts off and no more brine 
is being drawn into the softener (at the beginning of the slow 
rinse process). 
3)  Unplug the electric power leaving the softener control valve in 
the brine draw cycle.
4)  Remove the brine refill elbow assembly from the control valve.  
Remove the refill flow control retainer assembly from the elbow.  
Reinstall the elbow assembly and secure with the locking clip.  
Disconnect the brine tube at the top of the salt keeper and force 
air into the brine tube toward the softener mineral tank and control 
valve. The air will force the brine/water solution that was drawn 
into the mineral tank out to drain through the control valve drain 
line. (An air compressor blow gun attachment with a portable 
air compressor works well.)  Reinstall the brine line flow control 
retainer in side of the refill elbow assembly.  Reinstall the brine 
refill elbow assembly and secure with locking clip.
  CAUTION: You do not want to apply any more pressure than 
necessary to force the brine/water out of the mineral tank. 
  The small amount of brine/water that may be left in the mineral 
tank will not expand enough to cause any damage to the softener 
when it freezes.
  If your softener is equipped with an optional bottom drain on the 
mineral tank, you will have to follow all of the same procedures 
with  the  exception  of  the  need  for  compressed  air.  With  the 
brine tube disconnected from the salt keeper, raise it to a level 
above the softener control valve and temporarily secure it in this 
position. Now open the drain valve at the bottom of the mineral 
tank and allow  all brine/water to drain from the mineral tank.
  CAUTION:  If a hose is connected to the drain valve to direct the 
brine/water to a floor drain be sure it runs downward and is unob-
structed. When brine/water quits running at the drain, be sure to 
leave the drain valve open until you start the system up again.
5)  At this time the salt keeper has very little water left in it. What 
liquid is left in the salt keeper is saturated brine, provided that 
there is still salt left in the tank. Saturated brine will not freeze 
solid and cause any damage and does not have to be drained 
any further from the brine tank.
  If there is no salt left in the salt keeper when the system is drained 
we recommend dumping all of the water out of the brine tank 
at this time. See brine tank cleaning instructions. (#2 in miscel-
laneous section, below)
6)  CAUTION: It is important at this time to be assured that the inlet/
outlet water supply piping is properly drained. Depending on how 
the water supply piping was routed to the water softener control 
valve, a water loop or trap may have been created.
  Sometimes drain valve(s) are installed at the bottom of the loop 
to assure all water can be drained out. If not it may be neces-
sary to disconnect the control valve from the piping system and 
open the inlet/outlet valve(s) to allow all the water to drain from 
the piping. This should be done when the rest of the plumbing 
system is drained.
7)  Draining or winterizing of your softener is complete. Refer to the start-
up procedures on page 8 when you are ready to start your softener.
WaTer sOfTener DraininG prOCeDure