Hearth & Home Technologies CASTILE-CWL User Manual

Page of 48
R
September 1, 2008
250-6422E
Page  9
Castile Pellet Stove 
*L Exception for Horizontal Installations:
USA INSTALLATIONS: A non-combustible floor protection is 
recommended extending beneath the flue pipe when installed 
with horizontal venting or under the Top Vent Adapter with 
vertical installation.
CANADA INSTALLATIONS:  A non-combustible floor pro-
tection extending beneath the flue pipe is required with hori-
zontal venting or under the Top Vent Adapter with vertical 
installation.
Must extend 2 inches (51mm) beyond each
side of pipe  (shaded area)
C. Hearth Pad Requirements (UL and ULC)
Use a non-combustible floor protector, extending beneath 
appliance and to the front, sides and rear as indicated.  
Measure front distance “M” from the surface of the glass 
door.
Hearth Pad Requirements
Inches
Millimeters
K
Sides
2
51
L*
Back
2
51
M
Front
6
152
L*
K
K
M