StorageTek 312564001 User Manual

Page of 189
 
132 
DB2 Manager User Guide 
 StorageTek 
Proprietary 
 Explanation:  Identification of objects to be pre-fetch by Archive Manager cannot be 
performed via index-only processing, and a SQLIN parameter of 
INDEXONLY=Y has been specified (or defaulted).   Execution of the 
utility cannot continue, and is terminated with a condition code 12. 
 
Action:  Refer to a description of the INDEXONLY execution parameter on 
page 101 for a discussion of considerations regarding index-only 
processing by the row restore utility.   If necessary, change the setting 
of the INDEXONLY parameter and re-submit the job. 
 
OTD13015 
Archive Manager is not at the correct level 
 Explanation:  Archive Manager v2.6 or higher must be installed in order to be able 
to perform pre-fetch processing using the DB2 Manager pre-fetch 
utility.   The version of Archive Manager used during execution of the 
utility is not at the correct level. 
 
Action:  Ensure that the correct Archive Manager load library has been 
specified in the STEPLIB, JOBLIB or linklist library concatenations, 
and rerun the job.    
 
OTD13016 
Return Code xx, Supp codes X'yyyyyyyy' received during OPEN | 
CLOSE processing for Archive Manager database zzzz 
 Explanation:  An error has been received from an Archive Manager open or close 
request.  ‘xx’ gives the return code and ‘yyyyyyyy’ the hexadecimal 
supplementary reason codes received from Archive Manager.   
Execution of the utility has been terminated with condition code 12. 
 
Action:  Refer to the Archive Manager User Manual for a description of the 
return and supplementary codes displayed in the message.  Take the 
appropriate corrective action and re-submit the job.   If no obvious 
reason for the error can be identified, contact your local STK support 
representative. 
 
OTD140xx – table analysis utility messages 
Messages from the DB2 Manager table analysis utility will be written to the SYSPRINT 
dataset. 
 
OTD14000   Table Analysis Utility ended with completion code xx 
 Explanation:  The DB2 Manager table analysis utility has terminated. ‘xx’ gives the 
job completion code.  This can take the following values: 
0 -   the utility has been executed successfully. 
4 -   a warning condition has been encountered during processing of 
 
the utility.  A warning message will have been written to the