OTD20083 Task 
tnnn has not been purged – request ignored   
 Explanation:   A FORCE request has been entered for task 'tnnn', where ‘t’ identifies 
the sub-task type (‘D’ – disk reader; ‘H’ – housekeeping;  ‘S’ – 
scheduler; ‘T’ – tape reader; ‘W’ – writer) and ‘nnn’ gives the sub-task 
number, but no prior PURGE request has been entered.  A PURGE 
request must already have been entered for a task before a FORCE 
request is accepted.  The request is ignored. 
 
Action:   Enter a PURGE request for the task.  All outstanding retrieval 
requests will be completed before the specified task is terminated.  If 
necessary a FORCE request may then be entered for the task. 
 
OTD20091 
Invalid Shutdown operand(s) 
 Explanation:  An invalid operand has been entered with the operator SHUTDOWN 
command. 
 
for details of the operator SHUTDOWN command  format. 
 
OTD20092 
Do you want to proceed with shutdown (y/n)? 
 Explanation:  An operator SHUTDOWN request has been  entered on the console 
via the operator reply facility. This message is displayed to ask for 
confirmation of the shutdown request. 
 
Action:  To proceed with DB2 Manager control region shutdown processing, 
enter 'Y'. 
 
  To abort the shutdown request, enter 'N'. The operator reply message 
OTD20000 will then be redisplayed. 
 
OTD20093 
Shutdown in progress 
 Explanation:  An operator SHUTDOWN request has been entered and accepted.  
Termination of the control region will continue. 
 
Action:  None.  This is an informational message only. 
 
OTD20094 
Error freeing communications table storage 
 Explanation:  The storage area allocated in subpool 241 in the MVS ECSA during 
control region initialization processing for the DB2 Manager 
communications table was not freed successfully during control region 
shutdown.  Termination processing continues. 
 
Action:  Refer to other available system messages for more information 
regarding the error.  When the cause has been identified, take the 
appropriate corrective action to ensure that the error does not re-
occur during future shutdown of the control region.