StorageTek 312564001 User Manual

Page of 189
 
 
DB2 Manager User Guide 
35 
 StorageTek 
Proprietary 
 
 
record. Individual keyword parameters may not be continued over more than 
one record. 
An asterisk ('*') in character position 1 will indicate a comment record, which 
will be ignored for parameter validation processing. 
Any departure from this general format will be indicated with individual 
parameter descriptions. 
 
ENVCNTL parameters 
These parameters are used to pass information to DB2 Manager about its 
operating environment, and to control certain aspects of DB2 Manager 
operation which do not fall into the categories controlled by other parameter 
library members. 
Parameters in this member have the general parameter format described on 
page 34. 
ENVCNTL: SMFRECID 
 
SMFRECID = 0|nnn 
 
Requirement: Optional 
 Default: 
  Validation:  'nnn' = 3 numeric digits in the range 128-255. 
 
Use:  The SMFRECID parameter is used to control the creation of 
SMF records by DB2 Manager for the recording of migrated 
row storage and retrieval activities. 
 
  A value of 0 indicates that no SMF recording is to be 
performed by DB2 Manager. 
 
  A non-zero value (in the range 128-255) is used to specify the 
value of the identifier of the SMF records written by DB2 
Manager. The default value is 0 (ie) no SMF recording. 
 
usage, and for a description of the DB2 Manager SMF record 
layout.