Proprietary 
JCL requirements 
The following JCL may be used to execute the utility: 
//* 
//STEP100  EXEC PGM=OTDBP100,REGION=4096K 
//*     
//STEPLIB   DD  DSN=Database.Manager.load.library,DISP=SHR         
//          DD  DSN=Archive.Manager.load.library,DISP=SHR 
//*          
//SYSIN     DD  DSN=Execution.parameter.file,DISP=SHR    
//SQLIN     DD  DSN=Migration.criteria.file,DISP=SHR    
//SYSPRINT  DD  SYSOUT=* 
//* 
DD entries should be specified as follows: 
STEPLIB
Enter the names of the DB2 Manager and Archive Manager 
product load libraries. 
SYSPRINT:   This entry is used for all print reports created during utility 
execution.  
SYSIN: 
This is a sequential dataset or in-stream JCL file containing 
fixed-length 80 byte records, and is used for specification of the 
parameters used to control utility execution.  Refer to “SYSIN 
parameter specification” on page 82  for a description of how to 
specify parameter entries in this file. 
SQLIN: 
This is a sequential dataset or in-stream JCL file containing 
fixed-length 80 bytes records, and is used for specification of 
the migration selection criteria to be used by the utility for 
selection of rows for migration from DB2 to DB2 Manager.  
Refer to “SQLIN entry specification” on page 85 for a 
description of how to specify a migration selection criteria entry 
in this file. 
SYSIN parameter specification 
Parameters used to control execution of the utility are specified in file SYSIN.   
This must be a sequential dataset or in-stream JCL file containing one or 
more fixed-length 80-byte records, each record containing one or more 
separate parameter entries.  Each parameter entry must be completely 
contained within one record (ie) continuation of any single parameter entry 
from one record to another is not permitted. A single record may contain 
multiple parameter entries, each being separated by one or more spaces, 
and optionally a single comma (‘,’). 
A parameter entry has the general format: 
keyword = value 
Each keyword and its associated value are separated by an '=' sign, and 
optionally one or more spaces. The first keyword parameter in a record may 
begin in any character position from 1 onwards. Parameters may extend up