Condition codes 
The table migration utility will set a condition code on completion. This code 
may take the following values: 
0 -  
the utility has been executed successfully. 
4 -  
a warning condition has been encountered during processing 
of the utility.  A warning message will have been written to the 
SYSPRINT dataset.  The utility has been executed 
successfully. 
8 -  
an error condition has been encountered during processing of 
the utility.  An error message will have been written to the 
SYSPRINT dataset.  Execution of the utility has continued. 
12  -  
a serious error has been encountered during processing of the 
utility.  An error message will have been written to the 
SYSPRINT dataset.  Execution of the utility has been 
terminated. 
Utility failure and restart considerations 
If the table migration utility fails to complete successfully (return code greater 
than 8), consult the error report in the SYSPRINT dataset to identify the 
cause of the problem.  Refer to chapter 7 for a description of the message(s) 
appearing in the error report.   All rows successfully processed prior to the 
last successful commit point before failure will have been successfully 
migrated from DB2 to Archive Manager, and any access requests for those 
objects will be satisfied by DB2 Manager from the appropriate Archive 
Manager database. 
After correcting the error, the utility may be rerun with an execution parameter 
of “RESTART=YES” specified.   The utility will automatically restart 
processing from the last successful commit point during the failed execution.    
No other special actions need to be taken prior to re-starting the failed table 
migration job.   
Operator commands 
Execution of the utility may be terminated at any point by entering the 
following command through the system console: 
(STO)P jobname 
where ‘jobname’ is the name of the job used to execute the object 
management procedure. 
The utility will acknowledge receipt of this command via message OTD10023, 
and perform normal termination processing.  All database updates performed 
by the utility prior to termination will be committed, and the utility will 
terminate with a condition code of 4.