Hearth & Home Technologies SANTAFEI-B User Manual

Page of 52
R
September 1, 2008
7019-205C
Page  5
Santa Fe Pellet Insert
2
Getting Started
A. Design, Installation & Location Considerations
 
 
 
Damaged parts could impair safe 
operation. Do NOT install damaged, incomplete or substitute 
components.
1. Appliance Location
OT
Check building codes prior to installation.
•  Installation MUST comply with local, regional, state and 
national codes and regulations.
•  Consult insurance carrier, local building inspector, fire 
officials or authorities having jurisdiction over restrictions, 
installation inspection and permits.
It is a good idea to plan your installation on paper, using 
exact measurements for clearances and floor protection, 
before actually beginning the installation
Consideration must be given to:
•  Safety, convenience, traffic flow
•  Placement of the chimney and chimney connector.  
•  If you are not using an existing chimney, place the appli-
ance where there will be a clear passage for a factory-
built listed chimney through the ceiling and roof.  
•  Installing an optional outside air kit would affect the loca-
tion of the vent termination.
T O
   
If burning shelled field corn, you must use ap-
proved venting specifically designed for corn to prevent corro-
sion or degradation.  Follow the instructions from the venting 
manufacturer.
Since pellet exhaust can contain ash, soot or sparks, you 
must consider the location of:
• Windows
• Air 
Intakes
• Air 
Conditioner
•  Overhang, soffits, porch roofs, adjacent walls 
• Landscaping, 
vegetation
When locating vent and venting termination, vent above 
roof line when possible.
Marginal Location:
 Below peak
Location NOT recommended:
  Not the highest point of the roof
  Wind loading possible
Multi-level Roofs
Windward
Leeward
Recommended:
Outside Air Intake
on windward side
NOT recommended:
Outside Air Intake
on leeward side
Recommended Location:
 Above peak
Recommended:
  Insulated exterior chase 
in cooler climates
Recommended Location:
 Above peak
  Inside heated space
Location NOT recommended:
  Too close to tree
  Below ad acent structure
  Lower roof line
  Avoid outside wall
Marginal Location:
  Wind loading possible
OT
  Locating the appliance in a location of 
considerable air movement can cause intermittent smoke 
spillage from appliance. Do not locate appliance near:
• 
Frequently open doors
Central heat outlets or returns
Figure 5.1