GE 263 User Manual

Page of 44
40 
Troubleshooting
Rev A
System Troubleshooting
Problem
Possible Cause
Solution
1. Brine tank 
overflow.
a. Uncontrolled brine refill flow rate.
b. Air leak in brine line to air check.
c. Drain control clogged with resin 
or other debris.
a. Remove brine control to clean ball and seat.
b. Check all connections in brine line for leaks. 
Refer to instructions.
c. Clean drain control.
2. Flowing or 
dripping water at 
drain or brine line 
after 
regeneration.
a. Valve stem return spring weak.
b. Debris is preventing valve disc 
from closing.
a. Replace spring. (Contact dealer.)
b. Remove debris.
3. Hard water 
leakage after 
regeneration.
a. Improper regeneration.
b. Leaking of external bypass valve.
c. O-ring around riser pipe 
damaged.
d. Incorrect capacity.
a. Repeat regeneration after making certain 
correct regenerant dosage was set.
b. Replace bypass valve. (Contact dealer.)
c. Replace O-ring. (Contact dealer.)
d. Verify appropriate regenerant amount and 
system capacity. (Contact dealer.)
4. Control will not 
draw brine.
a. Low water pressure.
b. Restricted drain line.
c. Injector plugged.
d. Injector defective.
e. Valve disc 2 and/or 3 not closed.
f. Air check valve prematurely 
closed.
a. Make correct setting according to 
instructions.
b. Remove restriction.
c. Clean injector and screen.
d. Replace injector and cap. (Contact dealer.)
e. Remove foreign matter from disc and check 
disc for closing by pushing in on stem. 
Replace if needed. (Contact dealer.)
f. Put control momentarily into brine refill. 
Replace or repair air check if needed. 
(Contact dealer.)
5. Control will not 
regenerate 
automatically.
a. AC adapter or motor not 
connected.
b. Defective motor.
a. Connect power.
b. Replace motor. (Contact dealer.)
6. Control 
regenerates at 
wrong time of 
day.
a. Controller set incorrectly.
a. Correct time setting according to 
instructions.
7. Valve will not 
draw brine.
a. Low water pressure.
b. Restricted drain line.
c. Injector plugged.
d. Injector defective.
e. Air check valve closes 
prematurely on brine pickup 
tube.
a. Set pump to maintain 20 psi at softener.
b. Change drain to remove restriction.
c. Clean injector and screen.
d. Replace injector. (Contact dealer.)
e. Put control momentarily into brine/slow 
rinse. Replace or repair air check if needed. 
(Contact dealer.)
8. System using 
more or less salt 
than regenerant 
setting.
a. Foreign matter in valve causing 
incorrect flow rates.
a. Remove brine control and flush out foreign 
matter. Advance control to brine/slow rinse,  
to clean valve (after so doing position 
control to "fast rinse” to remove regenerant 
from tank).