GE RAK164D1 User Manual

Page of 16
Troubleshooting tips.
No display
Check for 24 VAC at thermostat;
display is blank when 24 VAC is 
not present.
System fan does not
Verify that wiring is correct.
come on properly
Thermostat turns on and
Adjust temperature differential
off too frequently
(see Temperature Differential,
Stage 1).
Fan runs continuously
Check Fan Auto/On switch. If set to
ON position, fan will run continuously.
Room temperature is 
Verify that wall hole is plugged 
not correct
with putty or insulation; calibrate
thermostat (see Configuration mode).
Auxiliary heat not on
Adjust differential for 2nd stage 
soon enough
(RAK148D1 only) heating, if required 
(see Configuration mode).
Compressor doesn’t run
There is a 3 minute time delay and 
or turn off immediately 
a 3 minute minimum run time for 
when changing function
the compressor when it turns on/off.
or setting
Fan doesn’t run or turn off
This is normal. On some models, the 
immediately when changing  fan may have a 3 minute minimum 
function or setting
run time/off time delay.
Problem not listed above
Press the Reset button once; 
display will be refreshed.
Problem
Solution