Kustom Profile System Two User Manual

Page of 20
2
ENGLISH
Danger
Exposure to extremely high noise levels may cause a 
permanent hearing loss. Individuals vary considerably to 
noise induced hearing loss but nearly everyone will lose 
some hearing if exposed to sufficiently intense noise for a 
sufficient time. 
The U.S. Government's Occupational Safety and Health 
Administration (OSHA) has specified the following 
permissible noise level exposures: 
According to OSHA, any exposure in the above permissible 
limits could result in some hearing loss. Ear plugs or 
protectors in the ear canal or over the ears must be worn 
when operating this amplification system in order to prevent 
a permanent hearing loss. If exposure in excess of the limits 
as put forth above, to insure against potentially harmful 
exposure to high sound pressure levels, it is recommended 
that all persons exposed to equipment capable of inducing 
high sound pressure levels, such as this amplification 
system, be protected by hearing protectors while this unit is 
in operation.
THIS SYMBOL IS INTENDED TO ALERT THE USER TO THE PRESENCE 
OF NON-INSULATED  "DANGEROUS VOLTAGE" WITHIN THE 
PRODUCT'S ENCLOSURE THAT MAY BE OF SUFFICIENT MAGNITUDE 
TO CONSTITUTE  A RISK OF ELECTRIC SHOCK TO PERSONS.
THIS SYMBOL IS INTENDED TO ALERT THE USER TO THE PRESENCE 
OF IMPORTANT OPERATING AND MAINTENANCE (SERVICING) 
INSTRUCTIONS IN THE LITERATURE ACCOMPANYING THE UNIT.
1.  Read all safety and operating instructions before using this 
product.
2.  All safety and operating instructions should be kept for 
future reference.
3.
Read and understand all warnings listed on the operating 
instructions.
4 . Follow all operating instructions to operate this product.
5.  This product should not be used near water, i.e. Bathtub, 
sink,swimming pool, wet basement, etc.
6.  Only use dry cloth to clean this product.
7.  Do not block any ventilation openings, It should not be 
placed flat against a wall or placed in a built-in enclosure 
that will impede the flow of cooling air.
8.
 Do not install this product near any heat sources ;such 
as,radiators, heat registers, stove or other apparatus 
(including heat producing amplifiers) that produce heat.
9.  Do not defeat the safety purpose of the polarized or 
grounding-type plug. A polarized plug has two blades with 
one wider than the 0ther.A grounding-type plug has two 
blades and a third grounding prong. The wide blade or the 
third prong are provided for your safety If the provided plug 
does not fit into your outlet, consult an electrician for 
replacement of the obsolete outlet.
10. Protect the power cord being walked on or pinched, 
particularly at Plugs, convenience receptacles and the point 
where they exit from the apparatus. Do not break the ground 
pin of the power supply cord.
11 . Only use attachments specified by the manufacturer.
12. Use only with the cart, stand, tripod, bracket, 
        or table specified by the manufacturer or 
        sold with the apparatus. When a cart is 
        used, use  caution when moving cart/
        apparatus combination to avoid injury
        from tip-over.
13. Unplug this apparatus during lightning storms or when 
unused for long periods of time.
14. Care should be taken so that objects do not fall and liquids 
are not spilled into the unit through the ventilation ports or 
any other openings.
15. Refer all servicing to qualified service personnel. Servicing 
is required when the apparatus has been damaged in any 
way; such as, power-supply cord or plug is damaged, liquid 
has been spilled or objects have fallen into the apparatus, 
the apparatus has been exposed to rain or moisture, does 
not operate normally or has been dropped.
16. WARNING: To reduce the risk of fire or electric shock, do not 
expose this apparatus to rain or moisture.
IMPORTANT SAFETY INSTRUCTIONS
RISK OF ELECTRIC SHOCK
DO NOT OPEN
CAUTION:
 TO REDUCE THE RISK OF ELECTRIC SHOCK, DO 
NOT REMOVE CHASSIS. NO USER-SERVICEABLE 
PARTS INSIDE. REFER SERVICING TO QUALIFIED 
SERVICE PERSONNEL.
AVIS:   RISQUE DE CHOC ELECTRIQUE-NE PAS OUVRIR.
CAUTION
APPARATUS SHALL NOT BE EXPOSED TO DRIPPING OR SPLASHING 
AND THAT NO OBJECTS FILLED WITH LIQUIDS, SUCH AS VASES, 
SHALL BE PLACED ON THE APPARATUS.
DURATION PER DAY (HOURS)
SOUND LEVEL (dB)
8       6       4      3      2      1
90      93     95    97   100   103
S 3 1 2 5 A
S 3 1 2 5 A