Butler Audio MONAD A100 User Manual

Page of 11
condition in the case of a direct short circuit between the + and 
- output speaker binding posts. 
 
 
7. Over Temp Circuit Breaker:  Opens the speaker relay if the 
heatsink temperature exceeds 115 deg. C.  If this occurs, the 
amp will automatically begin operate again after the 
temperature has decreased sufficiently. 
 
 
NOTE:  BE CERTAIN THAT AIR FLOW IS COMPLETELY UNRESTRICTED 
ABOVE AND BELOW THE AMPLIFIER.     THIS AMP IS DESIGNED FOR 
USE ONLY AT ROOM TEMPERATURE WITH ADEQUATE OPEN 
VENTILATION AND CIRCULATION.   IF ENCLOSED IN A CABINET, 
FORCED AIR VENTILLATION IS RECOMMENDED.   
 
IMPORTANT:  COOL OPERATION = LONGEST LIFE AND RELIABILITY!   
DO NOT OPERATE WITHIN A COMPLETELY CLOSED CABINET OR 
ENCLOSURE WITHOUT POSITIVE FORCED AIRFLOW! 
LET YOUR AMP BREATHE
! 
 
 
 
Use and Operation: 
Important:  Do not apply power until you have read and understand this section!   
Connect or disconnect cables only with amplifier OFF. 
 
Note:  Your new Butler MONAD amp is designed to operate with ONE separate speaker 
system connected.  Connect "Speaker Output" to speakers only!  DO NOT SHORT 
ACROSS SPEAKER OUTPUT POST TERMINAL.    
 
Power Switch: 
Supplies main AC power to the amplifier. The ON position is up and 
will be indicated by the illuminated blue 
Butler
  logo on the front 
panel.  The intensity of the logo is adjustable with the “Dimmer” 
control.