Bose MR-J2S- B User Manual

Page of 172
11 -  3
11. CHARACTERISTICS
11.2 Power supply equipment capacity and generated loss
(1) Amount of heat generated by the servo amplifier
Table 11.1 indicates servo amplifiers' power supply capacities and losses generated under rated load.
For thermal design of an enclosure, use the values in Table 11.1 in consideration for the worst
operating conditions. The actual amount of generated heat will be intermediate between values at
rated torque and zero torque according to the duty used during operation. When the servo motor is run
at less than the maximum speed, the power supply capacity will be smaller than the value in the
table, but the servo amplifier's generated heat will not change.
Table 11.1 Power supply capacity and generated heat per servo amplifier at rated output
(Note 2)
Servo amplifier-generated heat[W]
Area required for heat dissipation
Servo amplifier
Servo motor
(Note 1)
Power supply
capacity[kVA]
At rated torque
With servo off
[m
2
]
[ft
2
]
HC-KFS053 13
0.3
25
15
0.5
5.4
HC-MFS053 13
0.3
25
15
0.5
5.4
MR-J2S-10B(1)
HC-UFS13
0.3
25
15
0.5
5.4
HC-KFS23
0.5
25
15
0.5
5.4
HC-MFS23
0.5
25
15
0.5
5.4
MR-J2S-20B(1)
HC-UFS23
0.5
25
15
0.5
5.4
HC-KFS43
0.9
35
15
0.7
7.5
HC-MFS43
0.9
35
15
0.7
7.5
MR-J2S-40B(1)
HC-UFS43
0.9
35
15
0.7
7.5
HC-SFS52
1.0
40
15
0.8
8.6
MR-J2S-60B
HC-SFS53
1.0
40
15
0.8
8.6
MR-KFS73
1.3
50
15
1.0
10.8
HC-MFS73
1.3
50
15
1.0
10.8
MR-J2S-70B
HC-UFS72 73
1.3
50
15
1.0
10.8
HC-SFS81
1.5
50
15
1.0
10.8
MR-J2S-100B
HC-SFS102 103
1.7
50
15
1.0
10.8
HC-SFS121
2.1
90
20
1.8
19.4
HC-SFS201
3.5
90
20
1.8
19.4
HC-SFS152 153
2.5
90
20
1.8
19.4
HC-SFS202 203
3.5
90
20
1.8
19.4
HC-RFS103
1.8
90
20
1.8
19.4
HC-RFS153
2.5
90
20
1.8
19.4
MR-J2S-200B
HC-UFS152
2.5
90
20
1.8
19.4
HC-SFS301
4.8
120
20
2.7
29.1
HC-SFS352 353
5.5
130
20
2.7
29.1
HC-RFS203
3.5
90
20
1.8
19.4
MR-J2S-350B
HC-UFS202
3.5
90
20
1.8
19.4
HC-SFS502
7.5
195
25
3.9
42.0
HC-RFS353
5.5
135
25
2.7
29.1
HC-RFS503
7.5
195
25
3.9
42.0
HC-UFS352
5.5
195
25
3.9
42.0
MR-J2S-500B
HC-UFS502
7.5
195
25
3.9
42.0
MR-J2S-700B
HC-SFS702
10.0
300
25
6.0
64.6
Note:1. Note that the power supply capacity will vary according to the power supply impedance.
2. Heat generated during regeneration is not included in the servo amplifier-generated heat. To calculate heat generated by
the regenerative brake option, use Equation 12.1 in Section 12.1.1.