Crown Audio CH3 Leaflet

Page of 2
70V Stereo (per channel)
1 kHz 
Power
1,200W
600W
1,200W
2,400W
8 ohm Bridge-Mono
4 ohm Stereo (per channel)
8 ohm Stereo (per channel)
CH4
*1 kHz Power: refers to maximum average power in watts 
at 1 kHz with 0.5% THD.
*
2,400W
140V Bridge-Mono
1,400W**
2 ohm Stereo (per channel)
2,800W**
4 ohm Bridge-Mono
**
≥200V line voltage provides 1800W (2 ohm stereo) 
and 3600W (4 ohm bridge-mono).
70V Stereo (per channel)
1 kHz 
Power
300W
275W
450W
900W
8 ohm Bridge-Mono
4 ohm Stereo (per channel)
8 ohm Stereo (per channel)
CH1
 
*1 kHz Power: refers to maximum average power in watts 
at 1 kHz with 0.5% THD.
*
600W
140V Bridge-Mono
70V Stereo (per channel)
1 kHz 
Power
600W
400W
660W
1,320W
8 ohm Bridge-Mono
4 ohm Stereo (per channel)
8 ohm Stereo (per channel)
CH2
*1 kHz Power: refers to maximum average power in watts 
at 1 kHz with 0.5% THD.
*
1,200W
140V Bridge-Mono
CH1
C O N T R A C T O R   S E R I E S
L
ooking for a quality, constant voltage and low 
impedance two channel amplifi er for your res-
taurant, nightclub, retail store, school or house 
of worship projects? The Crown
®
 “Contractor Series” 
amplifi ers are designed just for you.
CH-Series amplifi ers can directly drive “constant 
voltage” lines, so you can avoid the expense of 
adding step-up transformers for distributed loud-
speaker systems. 
All Contractor-Series amplifi ers feature Crown’s 
exclusive SST (System Solutions Topologies) expan-
sion system. The SST expansion system makes it 
easy to tailor your amplifi er to a specifi c application 
or to add future technology as it develops.
With an incredibly wide range of power and fea-
ture/benefi ts, Contractor-Series amplifi ers give the 
professional sound contractor more options. Crown 
quality is available at the best dollar-per-watt ratio on 
the market.
For more details about the Crown Contractor Series, 
contact the Crown Technical Support Group at 800-
342-6939 or 574-294-8200. Also, visit the Crown 
Audio website at www.crownaudio.com.
Specifi cations
Note: All measurements apply to amplifi ers in stereo 
mode with 8 ohm loads and an input sensitivity of 26 
dB gain, 1 kHz at rated power unless other otherwise 
specifi ed. Specifi cations  for units supplied outside 
the U.S.A. may vary slightly at different AC voltages 
and frequencies.
Power
Output Power: See power charts below.
Load Impedance:
Safe with all types of loads. 
4 and 8 ohm Stereo.
16 ohm (CH1) or 8 ohm (CH2) or 4 ohm (CH4) at 
70V Stereo.
4, 8 and 16 ohm Bridge.
32 ohm (CH1) or 16 ohm (CH2) or 8 ohm (CH4) at 
140V Bridge.
64 ohm (CH1) or 32 ohm (CH2) at 200V Bridge.
Voltage Gain, 1 kHz, 1.4V sensitivity:
30.5 dB (CH1) or 32.1 dB (CH2) or 34 dB (CH4) 
at 8 ohms.
34 dB (CH1) or 34 dB (CH2) or 34 dB (CH4) at 
70V.
AC Line Requirements:
Note: North American units are 60 Hz only. All other 
models are 50/60 Hz. Voltages are ±10%.
AC Line Current:
100V: 7.6A (CH1) or 11.4A (CH2) or 8.5A (CH4).
120V: 6.3A (CH1) or 9.5A (CH2) or 7.1A (CH4).
230-240V: 3.5A (CH1) or 5.0A (CH2) or 
3.7A (CH4).
AC Line Connector: Detachable 15A IEC connector 
with country-specifi c plug.
Performance
Frequency Response, 20 Hz to 20 kHz at 1 watt: ±0.1 
dB (CH1, CH2) or ±0.25 dB (CH4).
Phase Response: ±15 degrees deviation from linear 
phase from 20 Hz to 20 kHz at 1 watt.
Signal to Noise Ratio, A-Weighted: Better than 105 
dB (CH1, CH2) or 102 dB (CH4) below rated 1-kHz 
power.  
Total Harmonic Distortion (THD), 1 kHz at rated 
power:
 0.5% or less true THD from 20 Hz to 20 kHz.
Intermodulation Distortion (60 Hz and 7 kHz at 4:1): 
Less than 0.1% (CH1, CH2) or 0.5% (CH4) at rated 
power to 30 dB below rated power at 8 ohms.
Damping Factor (8 ohm): Better than 400 (CH1, CH2) 
or 700 (CH4) from 10 Hz  to 400 Hz.
Crosstalk, 20 Hz to 20 kHz: Better than 50 dB below 
rated power.
Common Mode Rejection (CMR): Better than 40 dB 
from 20 Hz to 1 kHz.
DC Output Offset (shorted Input): < ±10 mV.
Features
•  Drives multiple impedances, with both low 
impedance and high impedance outputs per 
channel.
•  High-pass filter for each channel provides 
low-frequency roll off to eliminate step down 
transformer saturation when used in 70V dis-
tributed systems.
•  Shallow chassis design, allowing for installa-
tion in most wall-mount racks.
•  Rear panel detented level controls allow for 
accurate level settings and secure operation.
•  “Contractor-Correct” barrier strip output con-
nectors allow for quick and easy connection, 
regardless of the load.
•  Advanced protection circuitry guards against: 
shorted outputs, open circuits, DC, mismatched 
loads, general overheating, high-frequency 
overloads and internal faults.
•  Can be mounted in standard (19-inch (48.3-
cm)) rack, shallow (14-inch (35.56-cm)) rack, 
or stacked on top of each other.
•  Accurate, uncolored sound with very low 
distortion for the best in music and voice repro-
duction.
•  Three-Year, No-Fault, Fully Transferable War-
ranty completely protects your investment and 
guarantees its specifi cations.
•     Crown’s Profi t Protection Plan guarantees quick, 
no-questions-asked replacement of your covered 
Contractor Series amplifi er should it fail at any 
time up to 6 months following date of installation. 
CH2