TESTING/TROUBLESHOOTING
Before finishing the installation, perform the 
following tests to make sure the wiring is correct 
and everything is operating properly.
Reconnect Battery
When wiring is complete, reconnect the battery 
negative terminal.
Test Power Wiring
Turn on the receiver, but do not turn up the 
volume. The amplifier power light should come 
on. If not, check the REM and +12V wires. Turn 
up the receiver volume slightly. All speakers 
should operate. If not, check wiring connections 
at amplifier and speakers.
Test Speaker Connections
These tests make sure the speakers are 
connected properly. If speakers don’t play at all, 
one (or both) speaker wires may be 
disconnected.
.
Troubleshooting
Problem
Possible Cause
Corrective Action
Amplifier does not 
turn on
No power to +12V terminal
Check fuse(s)
No power to REM terminal
Check head unit fuse(s) and wiring
Blown main fuse at battery
Replace fuse and identify cause of failure
Blown fuse at amplifier
Replace fuse and identify cause of failure
Faulty ground
Reground main power ground to bare metal chassis
Volume control too 
sensitive
Input level control adjusted too 
high
Readjust the input level
Distorted sound
Input level control adjusted too 
high
Readjust the input level
Blows fuse(s) at 
amp
Power wires connected backwards
Reconnect power wires properly
Internal problem with amp
Take unit for service
Engine noise / 
Alternator whine
Ground loop(s)
Use good quality shielded RCA cables
Faulty ground at amp
Reground amp to clean bare metal chassis
Faulty ground at head unit
Reground head unit to clean bare metal chassis
Inductive coupling
Reroute RCA and/or speaker wires away from factory 
harnesses
Input level on amp set too high
Readjust input level
Poor bass response Speakers out of phase
Check speaker polarity; reverse the connection to one 
speaker only if two subwoofers are connected to the 
amplifier.