Lucent Technologies 585-210-940 User Manual

Page of 106
 
 
Troubleshooting 
CentreVu CMS Release 3 Version 8 Disk-Mirrored Systems
Error messages
88
Error messages
4
The table that follows lists and explains error messages you can receive 
related to 
Solstice DiskSuite and disk mirroring. The messages are 
presented in alphabetical order, ignoring special characters and 
replacement strings. (For example, you would find the message 
filename restored”
 in alphabetical order by the word 
restored.)
Error Messages
Message:
All data on cms filesystems will be removed 
and filesystems will be unmirrored, are 
you sure?
Explanation: Standard warning message for
 olds -mirrored 
-cleanup
 command.
Response:
Always use an
 olds -mirrored -cleanup
 with 
caution, keeping in mind that a backup will be needed to 
recover any CMS data in the 
/cms filesystem. Use the 
command only to set up your system from scratch.
Message:
Attempt an operation on a submirror that 
has erred components.
Explanation: Component needs maintenance before the operation can 
be carried out.
Response:
1. Execute a 
metastat
 command. 
2. Examine the output for the 
Invoke line and execute 
the command named in that line. For example:
#
metareplace -e d13 c0t0d0s0
3. Reboot system.
Message:
CDROM must not be present, remove CD
Explanation: In order for the command to execute, the CDROM drive 
must be empty.
Response:
1. Enter the command:
eject
cdrom
2. Remove the CD from the drive tray.
3. Close the drive tray.