Emerson 20002158 User Manual

Page of 36
4-wire cable preparation
Figure 3-1:   
Cable layout
Run conduit to 
sensor
Metal conduit
Wrap the drain wires twice around the shield and cut off 
the excess drain wires.
Micro Motion
cable gland
Pass the wires 
through the gland.
Terminate the drain 
wires inside the 
gland.
Cable glands
Remove the core processor 
cover
Go to the shielding 
procedure
Done
(do not perform the 
shielding procedure)
Gland supplier
User-supplied
cable gland
Lay cable in conduit
Drain wires 
wrapped around 
shield
Gland type
Pass the wires through the gland nut and clamping insert.
Clamping
insert
Gland nut
1. Strip 4-1/2 inch (115 mm) of cable jacket.
2. Remove the clear wrap and filler material.
3. Strip all but 3/4 inch (19 mm) of shielding.
1. Strip 4-1/4 inch (108 mm) of cable jacket.
2. Remove the clear wrap and filler material.
3. Strip all but 1/2 inch (12 mm) of shielding.
NPT
M20
Wiring
Installation Manual 