GE DSKS333EC User Manual

Page of 3
For answers to your Monogram,
® 
GE Profile
 or  
GE
®
 appliance questions, visit our website at 
ge.com or call GE Answer Center
®
 service,  
800.626.2000.
360428
Specification Revised 5/09
Listed by 
Underwriters 
Laboratories
WSLP1100A/DSKS333EC 
GE Spacemaker
® 
Portable Washer and Stationary Dryer with Stack Rack DSR24RW
Dimensions and Installation Information (in inches) 
Washer Note: Washer wall outlet must be located within 36" of service cord entry. 
Wall outlet must not be located behind dryer.
Dryer Note: Dryer wall outlet must be located within 36" of service cord entry and 
accessible when dryer is mounted in position.
WSLP1500J
Portable
Washer
or
WSLS1500J
Stationary
Washer
DSKS433EB and
DSKS333EC
Dryer
Stack Rack
  DSDR24D
22-7/8
1-5/8
5-1/2
20
79-1/4
38"
WSLP1500J
Portable
or
37-1/2"
WSLS1500J
Stationary
24-1/2
25-1/2
31-1/2
Top
Vent
WSLP1100A
Stationary
Washer
DSKS333EC
Dryer
Stack Rack
  DSDR24D
22-7/8
1-5/8
5-1/2
20
77-3/4
38
25-1/2
Top
Vent
31-1/2
stack rack DSR24 w/DDP1380T
24-1/2
33-1/4
46
33-1/4
Special Installation Requirements
Alcove or Closet Installation:
 
•  If your dryer is approved for installation in an alcove or closet, it will be stated on 
a label on the dryer back.
• The dryer MUST be exhausted to the outside. 
•  Minimum clearances between dryer cabinet and adjacent walls or other 
surfaces are: 
    0" either side 
       3" front and rear
• Minimum vertical space from floor to overhead cabinets, ceilings, etc. is 52”. 
•  Closet doors must be louvered or otherwise ventilated and must contain a 
minimum of 60 sq. in. of open area equally distributed. If this closet contains 
both a washer and a dryer, doors must contain a minimum of 120 sq. in. of open 
area equally distributed.
•  No other fuel-burning appliance shall be installed in the same closet with  
a gas dryer.
Bathroom or Bedroom Installation:
• The dryer MUST be exhausted to the outdoors. 
•  The installation must conform with the local codes, or in the absence of local 
codes, with the National Electric Code and National Fuel Gas Code, ANSI Z223 
for gas dryers.
Minimum Clearances other than Alcove or Closet Installation:
•  Minimum clearances to combustible surfaces 
    0" both sides
       3" rear